Search results
Results From The WOW.Com Content Network
However, ICRP states: [1] "The quantities equivalent dose and effective dose should not be used to quantify higher radiation doses or to make decisions on the need for any treatment related to tissue reactions [i.e., deterministic effects].
Thus for example, an absorbed dose of 1 Gy by alpha particles will lead to an equivalent dose of 20 Sv, and an equivalent dose of radiation is estimated to have the same biological effect as an equal amount of absorbed dose of gamma rays, which is given a weighting factor of 1. To obtain the equivalent dose for a mix of radiation types and ...
Provide high neutron dose rate for materials testing [quantified as displacements per atom]; the target is 30 displacements per atom per year or greater. Provide an irradiation length that is appropriate for fast reactor fuel testing; the target is 0.6 to 1 meter. Provide a large irradiation volume within the core region; the target is 7 liters.
Calculated dose from the neutron and gamma ray flash, 1.2 km from ground zero of the Little Boy fission bomb, air burst at 600 m. [54] [55] 4.5–6: Sv: Fatal acute doses during Goiânia accident: 5.1: Sv: Fatal acute dose to Harry Daghlian in 1945 criticality accident [56] 10 to 17: Sv: Fatal acute doses during Tokaimura nuclear accident.
Effective dose is a dose quantity in the International Commission on Radiological Protection (ICRP) system of radiological protection. [1]It is the tissue-weighted sum of the equivalent doses in all specified tissues and organs of the human body and represents the stochastic health risk to the whole body, which is the probability of cancer induction and genetic effects, of low levels of ...
The International Committee for Weights and Measures states: "In order to avoid any risk of confusion between the absorbed dose D and the dose equivalent H, the special names for the respective units should be used, that is, the name gray should be used instead of joules per kilogram for the unit of absorbed dose D and the name sievert instead ...
This method produces a neutron beam with depth dose characteristics roughly similar to those of a 4 MV photon beam. The deuterons are accelerated using a gantry mounted superconducting cyclotron (GMSCC), eliminating the need for extra beam steering magnets and allowing the neutron source to rotate a full 360° around the patient couch.
It is often indicated in micrograys per hour (μGy/h) [1] or as an equivalent dose rate Ḣ T in rems per hour (rem/hr) or sieverts per hour (Sv/h). [ 2 ] [ 3 ] Dose and dose rate are used to measure different quantities [ 1 ] in the same way that distance and speed are used to measure different quantities.