When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Synchronverter - Wikipedia

    en.wikipedia.org/wiki/Synchronverter

    Figure 5. Compact control structure for a grid-connected inverter. Since a synchronous generator is inherently synchronized with the grid, it is possible to integrate the synchronization function into the power controller without synchronization unit. [17] This results in a compact control unit, as shown in the figure 4.

  3. Synchronization (alternating current) - Wikipedia

    en.wikipedia.org/wiki/Synchronization...

    In an alternating current (AC) electric power system, synchronization is the process of matching the frequency, phase and voltage of a generator or other source to an electrical grid in order to transfer power. If two unconnected segments of a grid are to be connected to each other, they cannot safely exchange AC power until they are ...

  4. Short circuit ratio (electrical grid) - Wikipedia

    en.wikipedia.org/wiki/Short_circuit_ratio...

    [citation needed] In a traditional grid dominated by synchronous generators, a strong grid with SCR greater than 3.0 will have the desired voltage stability and active power reserves. [4] A weak grid (with SCR values between 2.0 and 3.0 [6]) can exhibit voltage instability and control problems. [5] A grid with SCR below 2.0 is very weak. [6]

  5. Droop speed control - Wikipedia

    en.wikipedia.org/wiki/Droop_speed_control

    Droop speed control is a control mode used for AC electrical power generators, whereby the power output of a generator reduces as the line frequency increases. It is commonly used as the speed control mode of the governor of a prime mover driving a synchronous generator connected to an electrical grid.

  6. Inverter-based resource - Wikipedia

    en.wikipedia.org/wiki/Inverter-based_resource

    An inverter-based resource (IBR) is a source of electricity that is asynchronously connected to the electrical grid via an electronic power converter ("inverter"). The devices in this category, also known as converter interfaced generation (CIG), include the variable renewable energy generators (wind, solar) and battery storage power stations. [1]

  7. Grid-tie inverter - Wikipedia

    en.wikipedia.org/wiki/Grid-tie_inverter

    Grid-tie inverters are designed to disconnect quickly from the grid if the utility grid goes down. In the United States, there is an NEC requirement [ 2 ] that in the event of a blackout, the grid tie inverter shut down to prevent the electricity it generates from harming persons repairing the power grid.

  8. Capability curve - Wikipedia

    en.wikipedia.org/wiki/Capability_curve

    Due to high cost of a generator, a set of sensors and limiters will trigger the alarm when the generator approaches the capability-set boundary and, if no action is taken by the operator, will disconnect the generator from the grid. [3] D-curve expands with cooling. The D-curve for a particular generator can be expanded by improved cooling.

  9. Automatic generation control - Wikipedia

    en.wikipedia.org/wiki/Automatic_generation_control

    An electrical grid may have many types of generators and loads; generators must be controlled to maintain stable operation of the system. In an electric power system, automatic generation control (AGC) is a system for adjusting the power output of multiple generators at different power plants, in response to changes in the load. Since a power ...