When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    Power-factor correction increases the power factor of a load, improving efficiency for the distribution system to which it is attached. Linear loads with a low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the ...

  3. AC power - Wikipedia

    en.wikipedia.org/wiki/AC_power

    For instance, a power factor of 0.68 means that only 68 percent of the total current supplied (in magnitude) is actually doing work; the remaining current does no work at the load. Power Factor is very important in Power sector substations. Form the national grid the sub sectors are required to have minimum amount of power factor.

  4. Induction motor - Wikipedia

    en.wikipedia.org/wiki/Induction_motor

    The power factor of induction motors varies with load, typically from about 0.85 or 0.90 at full load to as low as about 0.20 at no-load, [39] due to stator and rotor leakage and magnetizing reactances. [45]

  5. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    When the load current exceeds the capability of the generator to supply both magnetization reactive power and load power the generator will immediately cease to produce power. The load must be removed and the induction generator restarted with either an external DC motor or if present, residual magnetism in the core. [2]

  6. Voltage regulation - Wikipedia

    en.wikipedia.org/wiki/Voltage_regulation

    Three power factor scenarios are shown, where (a) the line serves an inductive load so the current lags receiving end voltage, (b) the line serves a completely real load so the current and receiving end voltage are in phase, and (c) the line serves a capacitive load so the current leads receiving end voltage.

  7. Inductance - Wikipedia

    en.wikipedia.org/wiki/Inductance

    Inductive reactance is the opposition of an inductor to an alternating current. [21] It is defined analogously to electrical resistance in a resistor, as the ratio of the amplitude (peak value) of the alternating voltage to current in the component = = Reactance has units of ohms.

  8. Inrush current - Wikipedia

    en.wikipedia.org/wiki/Inrush_current

    To avoid magnetic inrush, only for transformers with an air gap in the core, the inductive load needs to be synchronously connected near a supply voltage peak, in contrast with the zero-voltage switching, which is desirable to minimize sharp-edged current transients with resistive loads such as high-power heaters.

  9. Load bank - Wikipedia

    en.wikipedia.org/wiki/Load_bank

    An inductive load consists of an iron-core reactive element which, when used in conjunction with a resistive load bank, creates a lagging power factor load. Typically, the inductive load will be rated at a numeric value 75% that of the corresponding resistive load such that when applied together a resultant 0.8 power factor load is provided.