When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Left atrial volume - Wikipedia

    en.wikipedia.org/wiki/Left_atrial_volume

    The left atrial volume is commonly measured by echocardiography or magnetic resonance tomography.It is calculated from biplane recordings with the equation: = where A4c and A2c denote LA areas in 4- and 2-chamber views respectively, and L corresponds to the shortest long-axis length measured in either views.

  3. Wiggers diagram - Wikipedia

    en.wikipedia.org/wiki/Wiggers_diagram

    Atrial pressure; Ventricular volume; Electrocardiogram; Arterial flow (optional) Heart sounds (optional) The Wiggers diagram clearly illustrates the coordinated variation of these values as the heart beats, assisting one in understanding the entire cardiac cycle. [1]

  4. Pressure–volume loop analysis in cardiology - Wikipedia

    en.wikipedia.org/wiki/Pressure–volume_loop...

    The net effect of these changes is that the width of the PV loop is increased (i.e., ventricular stroke volume is increased). However, ejection into the aorta (forward flow) is reduced. The increased ventricular stroke volume in this case includes the volume of blood ejected into the aorta as well as the volume ejected back into the left atrium.

  5. Left atrial enlargement - Wikipedia

    en.wikipedia.org/wiki/Left_atrial_enlargement

    By approximating the shape of the left atrium as an ellipsoid, its volume can be calculated from measurements of its dimensions along three perpendicular directions. [3] Indexing the left atrial volume to body surface area (volume/BSA) is recommended by the American Society of Echocardiography and the European Association of Echocardiography ...

  6. Pulmonary wedge pressure - Wikipedia

    en.wikipedia.org/wiki/Pulmonary_wedge_pressure

    Diagram of a pulmonary artery catheter in position. The pulmonary wedge pressure (PWP) (also called pulmonary arterial wedge pressure (PAWP), pulmonary capillary wedge pressure (PCWP), pulmonary artery occlusion pressure (PAOP), or cross-sectional pressure) is the pressure measured by wedging a pulmonary artery catheter with an inflated balloon into a small pulmonary arterial branch. [1]

  7. Ejection fraction - Wikipedia

    en.wikipedia.org/wiki/Ejection_fraction

    Modalities applied to measurement of ejection fraction is an emerging field of medical mathematics and subsequent computational applications. The first common measurement method is echocardiography, [7] [8] although cardiac magnetic resonance imaging (MRI), [8] [9] cardiac computed tomography, [8] [9] ventriculography and nuclear medicine (gated SPECT and radionuclide angiography) [8] [10 ...

  8. E/A ratio - Wikipedia

    en.wikipedia.org/wiki/E/A_ratio

    The E/A ratio is a marker of the function of the left ventricle of the heart. It represents the ratio of peak velocity blood flow from left ventricular relaxation in early diastole (the E wave) to peak velocity flow in late diastole caused by atrial contraction (the A wave). [1]

  9. Frank–Starling law - Wikipedia

    en.wikipedia.org/wiki/Frank–Starling_law

    A blood volume increase would cause a shift along the line to the right, which increases left ventricular end diastolic volume (x axis), and therefore also increases stroke volume (y axis). The Frank–Starling law of the heart (also known as Starling's law and the Frank–Starling mechanism ) represents the relationship between stroke volume ...