When.com Web Search

  1. Ads

    related to: how to calculate kap dose of insulin in ml measurement system

Search results

  1. Results From The WOW.Com Content Network
  2. Glucose clamp technique - Wikipedia

    en.wikipedia.org/wiki/Glucose_clamp_technique

    The hyperglycemic clamps are often used to assess insulin secretion capacity. Hyperinsulinemic-euglycemic clamp technique: The plasma insulin concentration is acutely raised and maintained at 100 μU/ml by a continuous infusion of insulin. Meanwhile, the plasma glucose concentration is held constant at basal levels by a variable glucose infusion.

  3. Homeostatic model assessment - Wikipedia

    en.wikipedia.org/wiki/Homeostatic_model_assessment

    IR is insulin resistance and %β is the β-cell function (more precisely, an index for glucose tolerance, i.e. a measure for the ability to counteract the glucose load). Insulin is given in μU/mL. [7] Glucose and insulin are both during fasting. [2] This model correlated well with estimates using the euglycemic clamp method (r = 0.88). [2]

  4. Disposition index - Wikipedia

    en.wikipedia.org/wiki/Disposition_index

    Disposition metrics integrate beta cell function and insulin sensitivity in a way so that the results remain constant across dynamical compensation. Changed from Cobelli et al. 2007 and Hannon et al. 2018 [1] [2] The Disposition index (DI) is a measure for the loop gain of the insulin-glucose feedback control system.

  5. Area under the curve (pharmacokinetics) - Wikipedia

    en.wikipedia.org/wiki/Area_under_the_curve...

    For example, gentamicin is an antibiotic that can be nephrotoxic (kidney damaging) and ototoxic (hearing damaging); measurement of gentamicin through concentrations in a patient's plasma and calculation of the AUC is used to guide the dosage of this drug. [3] AUC becomes useful for knowing the average concentration over a time interval, AUC/t.

  6. Minimed Paradigm - Wikipedia

    en.wikipedia.org/wiki/Minimed_Paradigm

    Pump and infusion set (catheter) placement Insulin basal bolus profile. Insulin pumps are drug delivery devices used to treat patients with type 1 and type 2 diabetes. The Minimed Paradigm REAL-Time and Continuous Glucose Monitoring (CGM) system, which received FDA clearance in 2006, uses tubing and a reservoir with rapid-acting insulin.

  7. Insulin (medication) - Wikipedia

    en.wikipedia.org/wiki/Insulin_(medication)

    Prandial insulin, also called mealtime or bolus insulin, is designed as a bolus dose of insulin prior to a meal to regulate the spike in blood glucose that occurs following a meal. The dose of prandial insulin may be static, or may be calculated by the patient using either their current blood sugar, planned carbohydrate intake, or both.

  8. Glucose tolerance test - Wikipedia

    en.wikipedia.org/wiki/Glucose_tolerance_test

    The glucose tolerance test was first described in 1923 by Jerome W. Conn. [4]The test was based on the previous work in 1913 by A. T. B. Jacobson in determining that carbohydrate ingestion results in blood glucose fluctuations, [5] and the premise (named the Staub-Traugott Phenomenon after its first observers H. Staub in 1921 and K. Traugott in 1922) that a normal patient fed glucose will ...

  9. Blood glucose monitoring - Wikipedia

    en.wikipedia.org/wiki/Blood_glucose_monitoring

    Blood glucose monitoring is the use of a glucose meter for testing the concentration of glucose in the blood ().Particularly important in diabetes management, a blood glucose test is typically performed by piercing the skin (typically, via fingerstick) to draw blood, then applying the blood to a chemically active disposable 'test-strip'.

  1. Ad

    related to: how to calculate kap dose of insulin in ml measurement system