Identification of these phases is challenging by traditional methods like X-ray diffraction (XRD) due to the peak overlap of ZnS and Cu 2 SnS 3 with CZTS. Some impurities such as ZnS and Cu 8 GeS 6 can be selectively removed from the CZTS or CZGS by treatment with hot diluted HCl. [9] Polymorphism could be another source of defects in CZTS.
X-ray diffraction is a generic term for phenomena associated with changes in the direction of X-ray beams due to interactions with the electrons around atoms. It occurs due to elastic scattering , when there is no change in the energy of the waves.
The units of the structure-factor amplitude depend on the incident radiation. For X-ray crystallography they are multiples of the unit of scattering by a single electron (2.82 m); for neutron scattering by atomic nuclei the unit of scattering length of m is commonly used.
X-ray powder diffractometer Bruker D8 Advance at FZU – Institute of Physics of the Czech Academy of Sciences. Laboratory X-ray diffraction equipment relies on the use of an X-ray tube, which is used to produce the X-rays. The most commonly used laboratory X-ray tube uses a copper anode, but cobalt and molybdenum are also popular.
X-ray optics is the branch of optics dealing with X-rays, rather than visible light. It deals with focusing and other ways of manipulating the X-ray beams for research techniques such as X-ray diffraction , X-ray crystallography , X-ray fluorescence , small-angle X-ray scattering , X-ray microscopy , X-ray phase-contrast imaging , and X-ray ...
An X-ray diffraction pattern of a crystallized enzyme. The pattern of spots (reflections) and the relative strength of each spot (intensities) can be used to determine the structure of the enzyme. The relative intensities of the reflections provides information to determine the arrangement of molecules within the crystal in atomic detail.
In crystallography, the R-factor (sometimes called residual factor or reliability factor or the R-value or R Work) is a measure of the disagreement between the crystallographic model and the experimental X-ray diffraction data - lower the R value lower is the disagreement or better is the agreement.
The Scherrer equation, in X-ray diffraction and crystallography, is a formula that relates the size of sub-micrometre crystallites in a solid to the broadening of a peak in a diffraction pattern. It is often referred to, incorrectly, as a formula for particle size measurement or analysis. It is named after Paul Scherrer.