Search results
Results From The WOW.Com Content Network
The basic components of a typical electron-beam processing device include: [1] an electron gun (consisting of a cathode, grid, and anode), used to generate and accelerate the primary beam; and, a magnetic optical (focusing and deflection) system, used for controlling the way in which the electron beam impinges on the material being processed ...
Electron-beam machining is a process in which high-velocity electrons are concentrated into a narrow beam with a very high planar power density. The beam cross-section is then focused and directed toward the work piece, creating heat and vaporizing the material. Electron-beam machining can be used to accurately cut or bore a wide variety of metals.
Electron beam therapy is performed using a medical linear accelerator.The same device can also be used to produce high energy photon beams. When electrons are required, the X-ray target is retracted out of the beam and the electron beam is collimated with a piece of apparatus known as an applicator or an additional collimating insert, constructed from a low melting point alloy.
Intraoperative electron radiation therapy is the application of electron radiation directly to the residual tumor or tumor bed during cancer surgery. [1] [2] Electron beams are useful for intraoperative radiation treatment because, depending on the electron energy, the dose falls off rapidly behind the target site, therefore sparing underlying healthy tissue.
In medicine, proton therapy, or proton radiotherapy, is a type of particle therapy that uses a beam of protons to irradiate diseased tissue, most often to treat cancer.The chief advantage of proton therapy over other types of external beam radiotherapy is that the dose of protons is deposited over a narrow range of depth; hence in minimal entry, exit, or scattered radiation dose to healthy ...
Accelerating voltages can be between 3 and 40 kV. When the accelerating voltage is 20–25 kV and the beam current is a few amperes, 85% of the electron's kinetic energy can be converted into thermal energy. Some of the incident electron energy is lost through the production of X-rays and secondary electron emission.
External beam radiation therapy (EBRT) is a form of radiotherapy that utilizes a high-energy collimated beam of ionizing radiation, from a source outside the body, to target and kill cancer cells. The radiotherapy beam is composed of particles, which are focussed in a particular direction of travel using collimators. [ 1 ]
Megavoltage X-rays are produced by linear accelerators ("linacs") operating at voltages in excess of 1000 kV (1 MV) range, and therefore have an energy in the MeV range. The voltage in this case refers to the voltage used to accelerate electrons in the linear accelerator and indicates the maximum possible energy of the photons which are subsequently produced. [1]