Search results
Results From The WOW.Com Content Network
Contact resistance values are typically small (in the microohm to milliohm range). Contact resistance can cause significant voltage drops and heating in circuits with high current. Because contact resistance adds to the intrinsic resistance of the conductors, it can cause significant measurement errors when exact resistance values are needed.
The simplest way to reduce voltage drop is to increase the diameter of the conductor between the source and the load, which lowers the overall resistance. In power distribution systems, a given amount of power can be transmitted with less voltage drop if a higher voltage is used. More sophisticated techniques use active elements to compensate ...
Either purchase power from another utility, usually at substantial prices, or reduce demand. Often utilities use load management systems to turn off customers' air conditioners, water heaters, and pool pumps to reduce demand. Voltage reduction has become another option for utilities to reduce demand—typically unbeknownst to the customer.
In electrical engineering, particularly power engineering, voltage regulation is a measure of change in the voltage magnitude between the sending and receiving end of a component, such as a transmission or distribution line. Voltage regulation describes the ability of a system to provide near constant voltage over a wide range of load ...
An I–V curve, showing the difference between static resistance (inverse slope of line B) and differential resistance (inverse slope of line C) at a point (A).. The resistance between two terminals of an electrical device or circuit is determined by its current–voltage (I–V) curve (characteristic curve), giving the current through it for any given voltage across it. [18]
An NTC thermistor's resistance is low at high temperatures. When the circuit is closed, the thermistor's resistance limits the initial current. After some time, current flow heats the thermistor, and its resistance changes to a lower value, allowing current to flow uninterrupted. It is inherently impossible for 100% of supply voltage to appear ...
The additional resistance increases power losses which, in power circuits, can generate undesirable heating. Proximity and skin effect significantly complicate the design of efficient transformers and inductors operating at high frequencies, used for example in switched-mode power supplies.
A time-domain reflectometer; an instrument used to locate the position of faults on lines from the time taken for a reflected wave to return from the discontinuity.. A signal travelling along an electrical transmission line will be partly, or wholly, reflected back in the opposite direction when the travelling signal encounters a discontinuity in the characteristic impedance of the line, or if ...