Search results

  1. Results From The WOW.Com Content Network
  2. Underfloor air distribution - Wikipedia

    en.wikipedia.org/wiki/Underfloor_air_distribution

    UFAD systems use an underfloor supply plenum located between the structural concrete slab and a raised floor system to supply conditioned air to supply outlets (usually floor diffusers), located at or near floor level within the occupied space. Air returns from the room at ceiling level or the maximum allowable height above the occupied zone.

  3. Air-mixing plenum - Wikipedia

    en.wikipedia.org/wiki/Air-mixing_plenum

    Air streams are mixed to save energy and improve energy efficiency by partially recirculating conditioned air.. The most common application for an air-mixing plenum is the mixing of return air (or extract air) with fresh air to provide a supply air mixture for onward distribution to the building or area which the ventilation system is serving. [1]

  4. Room air distribution - Wikipedia

    en.wikipedia.org/wiki/Room_air_distribution

    Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.

  5. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    Plenums are the central distribution and collection units for an HVAC system. The return plenum carries the air from several large return grilles (vents) or bell mouths to a central air handler. The supply plenum directs air from the central unit to the rooms which the system is designed to heat or cool.

  6. Displacement ventilation - Wikipedia

    en.wikipedia.org/wiki/Displacement_ventilation

    Displacement ventilation is best suited for taller spaces (higher than 3 meters [10 feet]). [2] Standard mixing ventilation may be better suited for smaller spaces where air quality is not as great a concern, such as single-occupant offices, and where the room height is not tall (e.g., lower than 2.3 meters [7.5 feet]).

  7. Plenum space - Wikipedia

    en.wikipedia.org/wiki/Plenum_space

    A plenum space is a part of a building that can facilitate air circulation for heating and air conditioning systems, by providing pathways for either heated/conditioned or return airflows, usually at greater than atmospheric pressure.