Search results
Results From The WOW.Com Content Network
Any mixture of methane and air will therefore lie on the straight line between pure methane and pure air – this is shown as the blue air-line. The upper and lower flammability limits of methane in air are located on this line, as shown (labelled UEL and LEL, respectively). The stoichiometric combustion of methane is: CH 4 + 2O 2 → CO 2 + 2H ...
A 5% displayed LFL reading for methane, for example, would be equivalent to 5% multiplied by 4.4%, or approximately 0.22% methane by volume at 20 degrees C. Control of the explosion hazard is usually achieved by sufficient natural or mechanical ventilation, to limit the concentration of flammable gases or vapors to a maximum level of 25% of ...
The lower flammability limit or lower explosive limit (LFL/LEL) represents the lowest air to fuel vapor concentration required for combustion to take place when ignited by an external source, for any particular chemical. [29] Any concentration lower than this could not produce a flame or result in combustion.
For each fuel, ignition occurs only within a certain range of concentration, known as the upper and lower flammability limits. For example, for methane and gasoline vapor, this range is 5-15% and 1.4-7.6% gas to air, respectively. An explosion can only occur when fuel concentration is within these limits [citation needed]
Methane vapor pressure vs. temperature. Uses formula log 10 P mm Hg = 6.61184 − 389.93 266.00 + T ∘ C {\displaystyle \log _{10}P_{\text{mm Hg}}=6.61184-{\frac {389.93}{266.00+T_{^{\circ }{\text{C}}}}}} given in Lange's Handbook of Chemistry , 10th ed. Note that formula loses accuracy near T crit = −82.6 °C
LHV calculations assume that the water component of a combustion process is in vapor state at the end of combustion, as opposed to the higher heating value (HHV) (a.k.a. gross calorific value or gross CV) which assumes that all of the water in a combustion process is in a liquid state after a combustion process.
You are free: to share – to copy, distribute and transmit the work; to remix – to adapt the work; Under the following conditions: attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made.
The lower flammability limit (LFL), [1] usually expressed in volume per cent, is the lower end of the concentration range over which a flammable mixture of gas or vapour in air can be ignited at a given temperature and pressure. The flammability range is delineated by the upper and lower flammability limits. Outside this range of air/vapor ...