When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Flammability diagram - Wikipedia

    en.wikipedia.org/wiki/Flammability_diagram

    Any mixture of methane and air will therefore lie on the straight line between pure methane and pure air – this is shown as the blue air-line. The upper and lower flammability limits of methane in air are located on this line, as shown (labelled UEL and LEL, respectively). The stoichiometric combustion of methane is: CH 4 + 2O 2 → CO 2 + 2H ...

  3. Flammability limit - Wikipedia

    en.wikipedia.org/wiki/Flammability_limit

    A 5% displayed LFL reading for methane, for example, would be equivalent to 5% multiplied by 4.4%, or approximately 0.22% methane by volume at 20 degrees C. Control of the explosion hazard is usually achieved by sufficient natural or mechanical ventilation, to limit the concentration of flammable gases or vapors to a maximum level of 25% of ...

  4. Methane - Wikipedia

    en.wikipedia.org/wiki/Methane

    Methane (US: / ˈ m ɛ θ eɪ n / METH-ayn, UK: / ˈ m iː θ eɪ n / MEE-thayn) is a chemical compound with the chemical formula CH 4 (one carbon atom bonded to four hydrogen atoms). It is a group-14 hydride, the simplest alkane, and the main constituent of natural gas.

  5. Limiting oxygen concentration - Wikipedia

    en.wikipedia.org/wiki/Limiting_oxygen_concentration

    For instance, to safely fill a new container or a pressure vessel with flammable gases, the atmosphere of normal air (containing 20.9 volume percent of oxygen) in the vessel would first be flushed (purged) with nitrogen or another non-flammable inert gas, thereby reducing the oxygen concentration inside the container. When the oxygen ...

  6. Purging (gas) - Wikipedia

    en.wikipedia.org/wiki/Purging_(gas)

    Assume a closed system (e.g. a container or process vessel), initially containing air, which shall be prepared for safe introduction of a flammable gas, for instance as part of a start-up procedure. The system can be flushed with an inert gas to reduce the concentration of oxygen so that when the flammable gas is admitted, an ignitable mixture ...

  7. Combustibility and flammability - Wikipedia

    en.wikipedia.org/.../Combustibility_and_flammability

    The lower flammability limit or lower explosive limit (LFL/LEL) represents the lowest air to fuel vapor concentration required for combustion to take place when ignited by an external source, for any particular chemical. [29] Any concentration lower than this could not produce a flame or result in combustion.

  8. Gas explosion - Wikipedia

    en.wikipedia.org/wiki/Gas_explosion

    For each fuel, ignition occurs only within a certain range of concentration, known as the upper and lower flammability limits. For example, for methane and gasoline vapor, this range is 5-15% and 1.4-7.6% gas to air, respectively. An explosion can only occur when fuel concentration is within these limits [citation needed]

  9. Glossary of fuel cell terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_fuel_cell_terms

    Flammability limits, also called flammable limits, give the proportion of combustible gases in a mixture, between which limits this mixture is flammable. Flash point The flash point of a flammable liquid is the lowest temperature at which it can form an ignitable mixture in air.