When.com Web Search

  1. Ads

    related to: dc current measurement sensor circuit

Search results

  1. Results From The WOW.Com Content Network
  2. Current sensing - Wikipedia

    en.wikipedia.org/wiki/Current_sensing

    Fiber optic current sensor, using an interferometer to measure the phase change in the light produced by a magnetic field. Rogowski coil, electrical device for measuring alternating current (AC) or high speed current pulses. Giant Magnetoresistance(GMR): Magnetic field sensor suitable for AC & DC Current with higher accuracy than Hall Effect.

  3. Rogowski coil - Wikipedia

    en.wikipedia.org/wiki/Rogowski_coil

    Traditional split-core current transformers do not require integrator circuits. The integrator is lossy, so the Rogowski coil does not have a response down to DC; neither does a conventional current transformer (see Néel effect coils for DC). However, they can measure very slow changing currents with frequency components down to 1 Hz and less ...

  4. Fiber-optic current sensor - Wikipedia

    en.wikipedia.org/wiki/Fiber-optic_current_sensor

    A fiber-optic current sensor (FOCS) is a device designed to measure direct current. Utilizing a single-ended optical fiber wrapped around the current conductor, [1] FOCS exploits the magneto-optic effect (Faraday effect). [2] The FOCS can measure uni- or bi-directional DC currents up to 600 kA, with an accuracy within ±0.1% of the measured value.

  5. Hall effect sensor - Wikipedia

    en.wikipedia.org/wiki/Hall_effect_sensor

    Hall effect current sensor with internal integrated circuit amplifier. 8 mm opening. Zero current output voltage is midway between the supply voltages that maintain a 4 to 8-volt differential. The non-zero current response is proportional to the voltage supplied and is linear to 60 amperes for this particular (25 A) device.

  6. Shunt (electrical) - Wikipedia

    en.wikipedia.org/wiki/Shunt_(electrical)

    Some alternatives to shunts can provide isolation from the high voltage by not directly connecting the meter to the high voltage circuit. Examples of devices that can provide this isolation are Hall effect current sensors and current transformers (see clamp meters). Current shunts are considered more accurate and cheaper than Hall effect devices.

  7. Current clamp - Wikipedia

    en.wikipedia.org/wiki/Current_clamp

    Current clamps are typically used to read the magnitude of alternating current (AC) and, with additional instrumentation, the phase and waveform can also be measured. Some clamp meters can measure currents of 1000 A and more. Hall effect and vane type clamps can also measure direct current (DC).

  8. Four-terminal sensing - Wikipedia

    en.wikipedia.org/wiki/Four-terminal_sensing

    Four-point measurement of resistance between voltage sense connections 2 and 3. Current is supplied via force connections 1 and 4. In electrical engineering, four-terminal sensing (4T sensing), 4-wire sensing, or 4-point probes method is an electrical impedance measuring technique that uses separate pairs of current-carrying and voltage-sensing electrodes to make more accurate measurements ...

  9. Direct current - Wikipedia

    en.wikipedia.org/wiki/Direct_current

    In electronics, it is common to refer to a circuit that is powered by a DC voltage source such as a battery or the output of a DC power supply as a DC circuit even though what is meant is that the circuit is DC powered. In a DC circuit, a power source (e.g. a battery, capacitor, etc.) has a positive and negative terminal, and likewise, the load ...