When.com Web Search

  1. Ad

    related to: transcapillary flow measurement procedure diagram

Search results

  1. Results From The WOW.Com Content Network
  2. Starling equation - Wikipedia

    en.wikipedia.org/wiki/Starling_equation

    As all blood vessels allow a degree of protein leak , true equilibrium across the membrane cannot occur and there is a continuous flow of water with small solutes. The molecular sieving properties of the capillary wall reside in a recently-discovered endocapillary layer rather than in the dimensions of pores through or between the endothelial ...

  3. Instrumentation in petrochemical industries - Wikipedia

    en.wikipedia.org/wiki/Instrumentation_in...

    Schematic of pump minimum flow protection arrangement. Large process pumps are provided with minimum flow protection. [4] This comprises measurement of flow (FE) at the pump discharge, this measurement is an input to a flow controller (FIC) whose set point is the minimum flow required through the pump(see diagram).

  4. Flow measurement - Wikipedia

    en.wikipedia.org/wiki/Flow_measurement

    Flow measurement is the ... This reference flow value is compared with the simultaneous flow value given by the flow measurement to be calibrated. The procedure is ...

  5. Piping and instrumentation diagram - Wikipedia

    en.wikipedia.org/wiki/Piping_and_instrumentation...

    A piping and instrumentation diagram (P&ID) is defined as follows: A diagram which shows the interconnection of process equipment and the instrumentation used to control the process. In the process industry, a standard set of symbols is used to prepare drawings of processes. The instrument symbols used in these drawings are generally based on ...

  6. ISO 10628 - Wikipedia

    en.wikipedia.org/wiki/ISO_10628

    ISO 10628 Diagrams for the chemical and petrochemical industry specifies the classification, content, and representation of flow diagrams. It does not apply to electrical engineering diagrams. ISO 10628 consists of the following parts: Part 1: Specification of Diagrams (ISO 10628-1:2014) [1] Part 2: Graphical Symbols (ISO 10628-2:2012)

  7. Capillary flow porometry - Wikipedia

    en.wikipedia.org/wiki/Capillary_flow_porometry

    It is widely used to measure minimum, maximum (or first bubble point) and mean flow pore sizes, and pore size distribution in membranes [1] nonwovens, paper, filtration and ultrafiltration media, hollow fibers, [2] ceramics, etc. In capillary flow porometry an inert gas is used to displace a liquid, which is in the pores. The pressure required ...

  8. Ultrasonic flow meter - Wikipedia

    en.wikipedia.org/wiki/Ultrasonic_flow_meter

    Schematic view of a flow sensor. An ultrasonic flow meter is a type of flow meter that measures the velocity of a fluid with ultrasound to calculate volume flow. Using ultrasonic transducers, the flow meter can measure the average velocity along the path of an emitted beam of ultrasound, by averaging the difference in measured transit time between the pulses of ultrasound propagating into and ...

  9. Incompressible flow - Wikipedia

    en.wikipedia.org/wiki/Incompressible_flow

    Anelastic flow: () =. Principally used in the field of atmospheric sciences, the anelastic constraint extends incompressible flow validity to stratified density and/or temperature as well as pressure. This allows the thermodynamic variables to relax to an 'atmospheric' base state seen in the lower atmosphere when used in the field of ...