When.com Web Search

  1. Ad

    related to: convert 12 awg to mm calculator free

Search results

  1. Results From The WOW.Com Content Network
  2. Circular mil - Wikipedia

    en.wikipedia.org/wiki/Circular_mil

    Likewise, since 1 inch is defined as exactly 25.4 mm, 1 mil is equal to exactly 0.0254 mm, so a similar conversion is possible from circular mils to square millimetres:

  3. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    However, AWG is dissimilar to IEC 60228, the metric wire-size standard used in most parts of the world, based directly on the wire cross-section area (in square millimetres, mm 2). The AWG tables are for a single, solid and round conductor. The AWG of a stranded wire is determined by the cross-sectional area of the equivalent solid conductor.

  4. Wire gauge - Wikipedia

    en.wikipedia.org/wiki/Wire_gauge

    No. 7/0, the largest size, is 0.50 inches (500 mils or 12.7 mm) in diameter (250 000 circular mils in cross-sectional area), and the smallest, No. 50, is 0.001 inches (1 mil or 25.4 μm) in diameter (1 circular mil [cross-sectional area] or 0.7854 millionths of a square inch).

  5. Standard wire gauge - Wikipedia

    en.wikipedia.org/wiki/Standard_wire_gauge

    No. 7/0, the largest size, is 0.50 in. (500 thou or 12.7 mm) dia., No. 1 is 0.30 in. ( 300 thou ), and the smallest, No. 50, is 0.001 in. ( 1 thou or 25.4 µm ). The system as a whole approximates an exponential curve , plotting diameter against gauge-number (each size is a approximately a constant multiple of the previous size).

  6. Body jewelry sizes - Wikipedia

    en.wikipedia.org/wiki/Body_jewelry_sizes

    For example, AWG 12g is 2.1 mm, but SWG 12g is 2.6 mm. AWG 8g happens to be the same as SWG 10g. AWG 000g is 10.4 mm, but SWG 000g is 9.4 mm. In most discussions of body jewelry, sizes are specified by giving the gauge, usually abbreviated by the suffix "g", the same symbol as used for grams : "12g".

  7. Aluminum building wiring - Wikipedia

    en.wikipedia.org/wiki/Aluminum_building_wiring

    Also, the size of the aluminum wire needs to be larger compared to copper wire used for the same circuit due to the increased resistance of the aluminum alloys. For example, a 15 A branch circuit supplying standard lighting fixtures can be installed with either #14 AWG copper building wire or #12 AWG aluminum building wire according to the NEC ...

  8. Electric power transmission - Wikipedia

    en.wikipedia.org/wiki/Electric_power_transmission

    Conductor sizes range from 12 mm 2 (#6 American wire gauge) to 1,092 mm 2 (2,156,000 circular mils area), with varying resistance and current-carrying capacity. For large conductors (more than a few centimetres in diameter), much of the current flow is concentrated near the surface due to the skin effect. The center of the conductor carries ...

  9. Birmingham gauge - Wikipedia

    en.wikipedia.org/wiki/Birmingham_gauge

    The Birmingham gauge ranges from 5/0 or 00000, the lowest gauge number corresponding to the largest size of 0.500 inches (12.7 mm), to 36, the highest gauge number corresponding to the smallest size of 0.004 inches (0.10 mm). The increments between gauge sizes are not linear and vary. [2]