  2. Stepper motor - Wikipedia

    en.wikipedia.org/wiki/Stepper_motor

    The US National Electrical Manufacturers Association (NEMA) standardises various dimensions, marking and other aspects of stepper motors, in NEMA standard (NEMA ICS 16-2001). [11] NEMA stepper motors are labeled by faceplate size, NEMA 17 being a stepper motor with a 1.7 by 1.7 inches (43 mm × 43 mm) faceplate and dimensions given in inches.

  3. Magnetic starter - Wikipedia

    en.wikipedia.org/wiki/Magnetic_starter

    A magnetic starter has a contactor and an overload relay, which will open the control voltage to the starter coil if it detects an overload on a motor. [1] [2] The overload relay opens a set of contacts that are wired in series with the supply to the contactor feeding the motor.

  4. DIN 72552 - Wikipedia

    en.wikipedia.org/wiki/DIN_72552

    wiper motor + in 1, 3, 54d, S 53a limit stop + 54, +2 53b limit stop field 3, 54e 53c washer pump 53e stop field 1, 2 53i wiper motor with permanent magnet, third brush for high speed Acoustic warning 71 beeper in H 71a beeper out, low 71b beeper out, high 72 hazard lights switch 85c hazard sound on Switches 81 opener 81a 1 out 81b 2 out 82 lock in

  5. Motor soft starter - Wikipedia

    en.wikipedia.org/wiki/Motor_soft_starter

    A motor soft starter is a device used with AC electrical motors to temporarily reduce the load and torque in the powertrain and electric current surge of the motor during start-up. This reduces the mechanical stress on the motor and shaft, as well as the electrodynamic stresses on the attached power cables and electrical distribution network ...

  6. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    A three-phase motor is more compact and less costly than a single-phase motor of the same voltage class and rating, and single-phase AC motors above 10 hp (7.5 kW) are uncommon. Three-phase motors also vibrate less and hence last longer than single-phase motors of the same power used under the same conditions. [32]

  7. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    In Europe, three-phase 230/400 V is most commonly used. However, 130/225 V, three-wire, two-phase electric power discontinued systems called B1 are used to run old installations in small groups of houses when only two of the three-phase high-voltage conductors are used. The phase shift in Europe is 120°, as is the case with three-phase current.

  8. NEMA size - Wikipedia

    en.wikipedia.org/wiki/NEMA_size

    NEMA (National Electrical Manufacturers Association) contactors and motor starters are rated by sizes. These sizes are grouped by rated current and power. [1] [2]

  9. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    NEMA 21 series devices are specified for three-pole plus neutral, five-wire grounding devices for 3-phase 120/208Y supplies. According to NEMA, NEMA 21 straight-blade devices are "reserved for future configurations", so no designs for this series exist and no devices have been manufactured.