  2. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  3. National Electrical Code - Wikipedia

    en.wikipedia.org/wiki/National_Electrical_Code

    The NEC also permits grounding-type receptacles in non-grounded wiring protected by a GFCI; this only applies when old non-grounded receptacles are replaced with grounded receptacles, and the new receptacles must be marked with 'No equipment ground' and 'GFCI Protected' . 240 V receptacle faces. The 1999 Code required that new 120/240 volt ...

  4. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    For power circuits, the color-coding uses the same colors as residential construction, and adds the additional wires used for three-phase systems. Black, Red and Blue are used for hot wires and White is used as the neutral wire in a 120/208 V circuit. Brown, Orange and Yellow are used as hot wires and gray is used as the neutral wire in a 277/ ...

  5. Multiway switching - Wikipedia

    en.wikipedia.org/wiki/Multiway_switching

    An intermediate switch can, however, be implemented by adding appropriate external wiring to an ordinary (six terminal) DPDT switch, or by using a separate DPDT relay. By connecting one or more 4-way (intermediate) switches in-line, with 3-way switches at either end, the load can be controlled from three or more locations.

  6. Three-prong adaptor - Wikipedia

    en.wikipedia.org/wiki/Three-prong_adaptor

    [2] [3] These adapters are illegal in some jurisdictions, in particular throughout Canada. [4] A safer and more reliable alternative identified in the US and Canadian electrical codes is to replace the outlet with a Ground Fault Circuit Interrupter (GFCI) breaker outlet. [3] Cheater plugs are also used to break ground loops in audio systems. [5]

  7. IEC 60364 - Wikipedia

    en.wikipedia.org/wiki/IEC_60364

    IEC 60364 Electrical Installations for Buildings is the International Electrotechnical Commission (IEC)'s international standard on electrical installations of buildings.This standard is an attempt to harmonize national wiring standards in an IEC standard and is published in the European Union by CENELEC as "HD 60364".

  8. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    IEC 60309 (formerly IEC 309 and CEE 17, also published by CENELEC as EN 60309) is a series of international standards from the International Electrotechnical Commission (IEC) for "plugs, socket-outlets and couplers for industrial purposes".

  9. Earth-leakage circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    A wire break in the fault to load section, or in the earth to ground section, will disable operation of the devices. Requirement of an additional third wire from the load to the devices. Separate devices cannot be grounded individually. Any additional connection to Earth on the protected system can disable the detector.