  1. Results From The WOW.Com Content Network
  2. Combustibility and flammability - Wikipedia

    en.wikipedia.org/.../Combustibility_and_flammability

    A fire test can be conducted to determine the degree of flammability. Test standards used to make this determination but are not limited to the following: Underwriters Laboratories UL 94 Flammability Testing; International Electrotechnical Commission IEC 60707, 60695-11-10 and 60695-11-20; International Organization for Standardization ISO 9772 ...

  3. Flame spread - Wikipedia

    en.wikipedia.org/wiki/Flame_spread

    This test method measures flame growth on the underside of a horizontal test specimen, using the Steiner tunnel test. The result is derivation of a Flame Spread Index ( FSI ), [ 2 ] which is a non-dimensional number which is placed on a relative scale in which asbestos-cement board has a value of 0, and red oak wood has 100.

  4. Fire test - Wikipedia

    en.wikipedia.org/wiki/Fire_test

    Fire test in Sweden, showing rapid fire spread through burning of cable jackets from one cable tray to another. A fire test is a means of determining whether fire protection products meet minimum performance criteria as set out in a building code or other applicable legislation.

  5. UL 94 - Wikipedia

    en.wikipedia.org/wiki/UL_94

    UL 94, the Standard for Safety of Flammability of Plastic Materials for Parts in Devices and Appliances testing, is a plastics flammability standard released by Underwriters Laboratories of the United States. [1] The standard determines the material's tendency to either extinguish or spread the flame once the specimen has been ignited.

  6. Maximum experimental safe gap - Wikipedia

    en.wikipedia.org/wiki/Maximum_Experimental_Safe_Gap

    Maximum experimental safe gap (MESG) is a standardized measurement of how easily a gas flame will pass through a narrow gap bordered by heat-absorbing metal. MESG is used to classify flammable gases for the design and/or selection of electrical equipment in hazardous areas, and flame arrestor devices. [1]

  7. Fire-resistance rating - Wikipedia

    en.wikipedia.org/wiki/Fire-resistance_rating

    Construction of a test sample consists of a mockup of a section of concrete floor, with typical mechanical and electrical utility components (pipes and cables) penetrating the floor assembly. A firestop mortar is applied around the penetrations. The completed test sample is inserted into a furnace such that one side is exposed to a fire.

  8. NFPA 704 - Wikipedia

    en.wikipedia.org/wiki/NFPA_704

    "NFPA 704: Standard System for the Identification of the Hazards of Materials for Emergency Response" is a standard maintained by the U.S.-based National Fire Protection Association. First "tentatively adopted as a guide" in 1960, [ 1 ] and revised several times since then, it defines the " Safety Square " or " Fire Diamond " which is used to ...

  9. Steiner tunnel test - Wikipedia

    en.wikipedia.org/wiki/Steiner_tunnel_test

    The Steiner tunnel test is a widely used method of testing building interior wall and ceiling finishes for their ability to support and propagate fire, and for their tendency to emit smoke. The test was developed in 1944 by Al Steiner of Underwriters Laboratories , and has been incorporated as a reference into North American standards for ...