Search results
Results From The WOW.Com Content Network
The CSF/serum glucose ratio, also known as CSF/blood glucose ratio, is a measurement used to compare CSF glucose and blood sugar. Because many bacteria metabolize glucose, and because the blood–brain barrier minimizes transversal, the ratio can be useful in determining whether there is a bacterial infection in the CSF. The normal ratio is 0.6 ...
The deceleration parameter in cosmology is a dimensionless measure of the cosmic acceleration of the expansion of space in a Friedmann–Lemaître–Robertson–Walker universe. It is defined by: q = d e f − a ¨ a a ˙ 2 {\displaystyle q\ {\stackrel {\mathrm {def} }{=}}\ -{\frac {{\ddot {a}}a}{{\dot {a}}^{2}}}} where a {\displaystyle a} is ...
The osmol gap is typically calculated with the following formula (all values in mmol/L): = = ([+] + [] + []) In non-SI laboratory units: Calculated osmolality = 2 x [Na mmol/L] + [glucose mg/dL] / 18 + [BUN mg/dL] / 2.8 + [ethanol/3.7] [3] (note: the values 18 and 2.8 convert mg/dL into mmol/L; the molecular weight of ethanol is 46, but empiric data shows that it does not act as an ideal ...
The second row is the same generator with a seed of 3, which produces a cycle of length 2. Using a = 4 and c = 1 (bottom row) gives a cycle length of 9 with any seed in [0, 8]. A linear congruential generator (LCG) is an algorithm that yields a sequence of pseudo-randomized numbers calculated with a discontinuous piecewise linear equation.
Accidental release source terms are the mathematical equations that quantify the flow rate at which accidental releases of liquid or gaseous pollutants into the ambient environment which can occur at industrial facilities such as petroleum refineries, petrochemical plants, natural gas processing plants, oil and gas transportation pipelines, chemical plants, and many other industrial activities.
Plasma osmolality measures the body's electrolyte–water balance. [1] There are several methods for arriving at this quantity through measurement or calculation. Osmolality and osmolarity are measures that are technically different, but functionally the same for normal use.
The deceleration due to drag that a projectile with mass m, velocity v, and diameter d will experience is proportional to 1/BC, 1/m, v² and d². The BC gives the ratio of ballistic efficiency compared to the standard G1 projectile, which is a fictitious projectile with a flat base, a length of 3.28 calibers/diameters, and a 2 calibers ...
So the equation above should be balanced as the change in the AG away from normal (12) is similar to the change in bicarb away from normal (24). Mathematically, if the change in the numerator is similar to the change in the denominator, the delta ratio will be close to 1.