Search results
Results From The WOW.Com Content Network
Superheated steam was widely used in main line steam locomotives. Saturated steam has three main disadvantages in a steam engine: it contains small droplets of water which have to be periodically drained from the cylinders; being precisely at the boiling point of water for the boiler pressure in use, it inevitably condenses to some extent in the steam pipes and cylinders outside the boiler ...
Thermodynamic data is usually presented as a table or chart of function values for one mole of a substance (or in the case of the steam tables, one kg). A thermodynamic datafile is a set of equation parameters from which the numerical data values can be calculated.
The Mollier enthalpy–entropy diagram for water and steam. The "dryness fraction", x , gives the fraction by mass of gaseous water in the wet region, the remainder being droplets of liquid. An enthalpy–entropy chart , also known as the H – S chart or Mollier diagram , plots the total heat against entropy, [ 1 ] describing the enthalpy of a ...
A superheater is a device used to convert saturated steam or wet steam into superheated steam or dry steam. Superheated steam is used in steam turbines for electricity generation, in some steam engines, and in processes such as steam reforming. There are three types of superheaters: radiant, convection, and separately fired.
The steam thus produced is at the same temperature as the water below it. This is called saturated steam. If the steam is taken away from the boiler, in a pipe, and then further heat is applied to that steam, the steam can rise above the temperature of the water in the boiler. This heated-above-the-boiler-temperature steam is called "superheated".
The specific heat of the human body calculated from the measured values of individual tissues is 2.98 kJ · kg−1 · °C−1. This is 17% lower than the earlier wider used one based on non measured values of 3.47 kJ · kg−1· °C−1.
Steam engines use water vapor to push pistons or turbines, and that movement creates work. The quantitatively described steam quality (steam dryness) is the proportion of saturated steam in a saturated water/steam mixture. In other words, a steam quality of 0 indicates 100% liquid, while a steam quality of 1 (or 100%) indicates 100% steam.
The energy required to heat water is significantly lower than that needed to vaporize it, for example for steam distillation [10] and the energy is easier to recycle using heat exchangers. The energy requirements can be calculated from steam tables. For example, to heat water from 25 °C to steam at 250 °C at 1 atm requires 2869 kJ/kg.