When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    Neutral is a circuit conductor that normally completes the circuit back to the source. NEC states that the neutral and ground wires should be connected at the neutral point of the transformer or generator, or otherwise some "system neutral point" but not anywhere else. [ 1 ]

  3. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    For power circuits, the color-coding uses the same colors as residential construction, and adds the additional wires used for three-phase systems. Black, Red and Blue are used for hot wires and White is used as the neutral wire in a 120/208 V circuit. Brown, Orange and Yellow are used as hot wires and gray is used as the neutral wire in a 277/ ...

  4. Distribution board - Wikipedia

    en.wikipedia.org/wiki/Distribution_board

    The neutral wire is connected to the neutral busbar to the left with all the white wires, and the two hot wires are attached to the main breaker. Below the main breaker are the two bus bars carrying the current between the main breaker and the two columns of branch circuit breakers, with each respective circuit's red and black hot wires leading ...

  5. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    A wire or cable has a voltage (to neutral) rating and a maximum conductor surface temperature rating. The amount of current a cable or wire can safely carry depends on the installation conditions. The international standard wire sizes are given in the IEC 60228 standard of the International Electrotechnical Commission.

  6. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    Three-phase systems may have a fourth wire, common in low-voltage distribution. This is the neutral wire. The neutral allows three separate single-phase supplies to be provided at a constant voltage and is commonly used for supplying multiple single-phase loads. The connections are arranged so that, as far as possible in each group, equal power ...

  7. Two-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Two-phase_electric_power

    Two-phase circuits typically use two separate pairs of current-carrying conductors. Alternatively, three wires may be used, but the common conductor carries the vector sum of the phase currents, which requires a larger conductor. The vector sum of balanced three-phase currents, however, is zero, allowing for the neutral wires to be eliminated.

  8. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    Three-pole common-trip breakers are typically used to supply three-phase power to powerful motors or further distribution boards. Separate circuit breakers must never be used for live and neutral, because if the neutral is disconnected while the live conductor stays connected, a very dangerous condition arises: the circuit appears de-energized ...

  9. Earthing system - Wikipedia

    en.wikipedia.org/wiki/Earthing_system

    In a TN (terra–neutral) earthing system, one of the points in the supply transformer is directly connected with Earth, usually the neutral-star-point in a star-connected supply transformer, the same point from which a neutral (N) connection would be provided. Exposed-conductive-parts within a consumer installation are connected with Earth via ...