When.com Web Search

  1. Ads

    related to: hvac budget per square foot calculator for concrete

Search results

  1. Results From The WOW.Com Content Network
  2. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.

  3. ASHRAE 90.1 - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_90.1

    The proposed energy cost budget must be less than or equal to the baseline energy cost budget to achieve compliance. The performance approach is also used to demonstrate design energy efficiency, often expressed as percent better than ASHRAE Standard 90.1. Building designs will stated their performance as "40% better than ASHRAE 90.1-2007" or ...

  4. Gypsum concrete - Wikipedia

    en.wikipedia.org/wiki/Gypsum_concrete

    Gypsum concrete is lightweight and fire-resistant. A 1.5-inch slab of gypsum concrete weighs 13 pounds per square foot versus 18 pounds per square foot for regular concrete. [10] Even though gypsum concrete weighs less, it still has the same compressive strength as regular concrete, based on its application as underlayment or top coat flooring ...

  5. Dedicated outdoor air system - Wikipedia

    en.wikipedia.org/wiki/Dedicated_outdoor_air_system

    For example, a space requiring 5663 standard litre per minute (SLPM) (200 standard cubic feet per minute (SCFM)) of ventilation air and served with supply air that is 40% ventilation air, will require a box minimum setting of 14158 SLPM (500 SCFM) (i.e. 200/0.4) rather than the conventional practice of 5663 SLPM (200 SCFM). When the box ...

  6. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    R p = ventilation rate per person (cubic feet per minute (CFM) per person or cubic meters per minute per person) ACPH = Air changes per hour; D = Occupant density (square feet per occupant or square meters per occupant) h = Ceiling height (feet or meters) One cubic meter per minute = 16.67 liter/second

  7. Jay Gilberg bought a five-bedroom, 4,800-square-foot (446-sq-meter) home in the Los Angeles neighborhood of Pacific Palisades in June to merge two households, bringing his two … People 13 days ago