Search results

  1. Results From The WOW.Com Content Network
  2. Fuse cutout - Wikipedia

    en.wikipedia.org/wiki/Fuse_cutout

    In electrical distribution, a fuse cutout or cut-out fuse (often referred to as a cutout) is a combination of a fuse and a switch, used in primary overhead feeder lines and taps to protect distribution transformers from current surges and overloads. An overcurrent caused by a fault in the transformer or customer circuit will cause the fuse to ...

  3. Fuse (electrical) - Wikipedia

    en.wikipedia.org/wiki/Fuse_(electrical)

    Normal fast-blow fuses are the most general purpose fuses. A time-delay fuse (also known as an anti-surge or slow-blow fuse) is designed to allow a current which is above the rated value of the fuse to flow for a short period of time without the fuse blowing. These types of fuse are used on equipment such as motors, which can draw larger than ...

  4. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker. In three-phase systems, a fault may involve one or more phases and ground, or may occur only between phases. In a "ground fault" or "earth fault", current flows into the earth.

  5. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    A shunt-trip unit appears similar to a normal breaker and the moving actuators are ganged to a normal breaker mechanism to operate together in a similar way, but the shunt trip is a solenoid intended to be operated by an external constant-voltage signal, rather than a current, commonly the local mains voltage or DC. These are often used to cut ...

  6. Crowbar (circuit) - Wikipedia

    en.wikipedia.org/wiki/Crowbar_(circuit)

    Once triggered, they depend on the current-limiting circuitry of the power supply or, if that fails, the blowing of the line fuse or tripping the circuit breaker. The name is derived from having the same effect as throwing a crowbar over exposed power supply terminals to short the output.

  7. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    On a 3-phase circuit, a recloser is more beneficial than three separate fuse cutouts. For example, on a wye to delta conversion, when cutouts are used on the wye side and only 1 out of 3 of the cutout fuses open, some customers on the delta side have a low voltage condition, due to voltage transfer through the transformer windings. Low voltage ...

  8. Discover the latest breaking news in the U.S. and around the world — politics, weather, entertainment, lifestyle, finance, sports and much more.

  9. Inrush current limiter - Wikipedia

    en.wikipedia.org/wiki/Inrush_current_limiter

    An inrush current limiter is a component used to limit inrush current to avoid gradual damage to components and avoid blowing fuses or tripping circuit breakers.Negative temperature coefficient (NTC) thermistors and fixed resistors are often used to limit inrush current.