For example, such a regulation might limit the concentration of NOx to 55 ppmv in a dry combustion exhaust gas corrected to 3 volume percent O 2. As another example, a regulation might limit the concentration of particulate matter to 0.1 grain per standard cubic foot (i.e., scf) of dry exhaust gas corrected to 12 volume percent CO 2.
Accidental release source terms are the mathematical equations that quantify the flow rate at which accidental releases of liquid or gaseous pollutants into the ambient environment which can occur at industrial facilities such as petroleum refineries, petrochemical plants, natural gas processing plants, oil and gas transportation pipelines, chemical plants, and many other industrial activities.
The Gaussian air pollutant dispersion equation (discussed above) requires the input of H which is the pollutant plume's centerline height above ground level—and H is the sum of H s (the actual physical height of the pollutant plume's emission source point) plus ΔH (the plume rise due to the plume's buoyancy).
The fuel factor, f o, is the ratio of created CO 2 to depleted oxygen in a combustion reaction, used to check the accuracy of an emission measurement system. [1] It can be calculated using the equation f o = (20.9 - %O 2)/%CO 2,
As an example, a measured NO x concentration of 45 ppmv in a dry gas having 5 volume % O 2 is: 45 × ( 20.9 - 3 ) ÷ ( 20.9 - 5 ) = 50.7 ppmv of NO x. when corrected to a dry gas having a specified reference O 2 content of 3 volume %. Note: The measured gas concentration C m must first be corrected to a dry basis before using the above equation.
The fugitive air pollutant emission factors from relief valves, piping valves, open-ended piping lines or drains, piping flanges, sample connections, and seals on pump and compressor shafts are discussed and included in the report EPA-458/R-95-017, "Protocol for Equipment Leak Emission Estimates" which is included in the Chapter 5 section of AP ...
eGRID data is presented as an Excel workbook with data worksheets and a table of contents. The eGRID workbook contains data at the unit, generator, and plant levels and aggregated data by state, power control area, eGRID subregion, NERC region, and U.S. The workbook also includes a worksheet that displays the grid gross loss (%).
An emission intensity (also carbon intensity or C.I.) is the emission rate of a given pollutant relative to the intensity of a specific activity, or an industrial production process; for example grams of carbon dioxide released per megajoule of energy produced, or the ratio of greenhouse gas emissions produced to gross domestic product (GDP).