Ad
related to: are 15a receptacles acceptable for ground services
Search results
Results From The WOW.Com Content Network
NEMA 1-15P (two-pole, no ground) and NEMA 5-15P (two-pole with ground pin) plugs are used on common domestic electrical equipment, and NEMA 5-15R is the standard 15-ampere electric receptacle (outlet) found in the United States, and under relevant national standards, in Canada (CSA C22.2 No. 42 [1]), Mexico (NMX-J-163-ANCE) and Japan (JIS C 8303).
Ground-fault circuit interrupter (GFCI) protection is required on receptacles in wet locations and locations where there exists an easy path for fault current to travel to earth. This includes all receptacles intended to service kitchen counter surfaces, crawl spaces at or below grade level, basements, garages and accessory buildings, bathrooms ...
The ground tab is designed to be attached to the outlet faceplate screw, which is supposed to be connected to the building electrical ground. A cheater plug, AC ground lifter or three-prong/two-prong adapter is an adapter that allows a NEMA 5-15P grounding-type plug (three prongs) to connect to a NEMA 1-15R non-grounding receptacle (two slots).
The NEMA 5-15 plug has two flat parallel blades like NEMA 1-15, and a ground (earth) pin. [46] It is rated 15 A at 125 volts. The ground pin is longer than the line and neutral blades, such that an inserted plug connects to ground before power. The ground hole is officially D-shaped, although some round holes exist.
The ground connection can become oxidized and when the shells are made of metal any ground fault goes right through the hands of a person connecting/disconnecting a male and a female cable connector (unless the person wears insulating gloves). Incorrect use of the ground connector as a neutral was not uncommon.
A ground fault circuit interrupter (GFCI) is required for all receptacles in wet locations defined in the Code. The NEC also has rules about how many circuits and receptacles should be placed in a given residential dwelling, and how far apart they can be in a given type of room, based upon the typical cord length of small appliances.
Also, larger aluminum stranded building wire made with AA-8000 series alloy of aluminum is used for electrical services (e.g. service entrance conductors from the utility connection to the service breaker panel) and for larger branch circuits such as for sub-panels, ranges, clothes dryers and air-conditioning units.
Presence of uninterrupted ground fault may pose a significant safety risk: if the current exceeds 4 A – 5 A an electric arc develops, which may be sustained even after the fault is cleared. [28] For that reason, they are chiefly limited to underground and submarine networks, and industrial applications, where the reliability need is high and ...