Search results
Results From The WOW.Com Content Network
A titration curve is a curve in graph the x-coordinate of which represents the volume of titrant added since the beginning of the titration, and the y-coordinate of which represents the concentration of the analyte at the corresponding stage of the titration (in an acid–base titration, the y-coordinate usually represents the pH of the solution).
Titration curves for addition of a strong base to a weak acid with pK a of 4.85. The curves are labelled with the concentration of the acid. where K w represents the self-dissociation constant of water. Since K w = [H +][OH −], the term K w / [H +] is equal to [OH −], the concentration of hydroxide ions. At neutralization, T H is zero.
Similarly, if strong alkali is added to the mixture, the hydrogen ion concentration decreases by less than the amount expected for the quantity of alkali added. In Figure 1, the effect is illustrated by the simulated titration of a weak acid with pK a = 4.7. The relative concentration of undissociated acid is shown in blue, and of its conjugate ...
A typical titration curve of a diprotic acid, oxalic acid, titrated with a strong base, sodium hydroxide.Both equivalence points are visible. Titrations are often recorded on graphs called titration curves, which generally contain the volume of the titrant as the independent variable and the pH of the solution as the dependent variable (because it changes depending on the composition of the ...
Titration of a standard solution using methyl orange indicator. Titrate is in Erlenmeyer flask, titrant is in burette. acid + base → salt + water. For example: HCl + NaOH → NaCl + H 2 O. Acidimetry is the specialized analytical use of acid-base titration to determine the concentration of a basic (alkaline) substance using standard acid.
The first potentiometric titration was carried out in 1893 by Robert Behrend at Ostwald's Institute in Leipzig. He titrated mercurous solution with potassium chloride, potassium bromide, and potassium iodide. He used a mercury electrode along with a mercury/mercurous nitrate reference electrode. He found that in a cell composed of mercurous ...
The term also has two other, conflicting meanings. In titration, the titer is the ratio of actual to nominal concentration of a titrant, e.g. a titer of 0.5 would require 1/0.5 = 2 times more titrant than nominal. This is to compensate for possible degradation of the titrant solution.
The chief advantage over other types of titration is the selectivity offered by the electrode potential, as well as by the choice of titrant. For instance, lead ion is reduced at a potential of -0.60 V (relative to the saturated calomel electrode), while zinc ions are not; this allows the determination of lead in the presence of zinc. Clearly ...