When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Oxygen therapy - Wikipedia

    en.wikipedia.org/wiki/Oxygen_therapy

    A small portable M6 (B) cylinder holds 164 or 170 litres (5.8 or 6.0 cu ft) and weighs about 1.3 to 1.6 kilograms (2.9 to 3.5 lb). [62] These tanks can last 4–6 hours with a conserving regulator, [clarification needed] which adjust flow based on a person's breathing rate. Conserving regulators may not be effective for patients who breathe ...

  3. Portable oxygen concentrator - Wikipedia

    en.wikipedia.org/wiki/Portable_oxygen_concentrator

    With continuous flow units, oxygen delivery is measured in LPM (liters per minute). Providing continuous flow requires a larger molecular sieve and pump/motor assembly, and additional electronics. This increases the device’s size and weight (approximately 18–20 lbs). [13]

  4. Oxygen concentrator - Wikipedia

    en.wikipedia.org/wiki/Oxygen_concentrator

    In the first half-cycle, the first cylinder receives air from the compressor, which lasts about 3 seconds. During that time, the pressure in the first cylinder rises from atmospheric to about 2.5 times normal atmospheric pressure (typically 20 psi/138 kPa gauge, or 2.36 atmospheres absolute) and the zeolite becomes saturated with nitrogen.

  5. Self-contained breathing apparatus - Wikipedia

    en.wikipedia.org/wiki/Self-contained_breathing...

    Demand: 2000 psi to the regulator from the main valve, plus a bypass valve in case of failure, with a two-stage regulator reducing pressure to 50-100 psi. Pressure-Demand : Similar to demand, but with a spring in the diaphragm, which holds the admission valve open, for continuous air flow to the facepiece.

  6. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s, e.g. water. [clarify]

  7. Automatic bleeding valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_bleeding_valve

    The valve must always be installed vertically, usually at the top of a short vertical pipe. If the valve body is filled with water, the float moves upwards and closes the valve. If air collects in the valve body, the waterline lowers, as does the float, and the valve opens to release it. [4]

  8. Diving cylinder - Wikipedia

    en.wikipedia.org/wiki/Diving_cylinder

    Valve ejected due to mix up with valve threads 3/4"NPSM and 3/4"BSP(F) caused damage to a dive shop compressor room. [92] A valve ejected during filling due to incompatible thread killed the operator by impact to the chest. [38] A valve failed on a diver's emergency cylinder on a diving support vessel during preparation for a dive injuring five ...

  9. Demand valve oxygen therapy - Wikipedia

    en.wikipedia.org/wiki/Demand_Valve_Oxygen_Therapy

    Demand Valve Oxygen Therapy (DVOT) is a way of delivering high flow oxygen therapy using a device that only delivers oxygen when the patient breathes in and shuts off when they breathe out. DVOT is commonly used to treat conditions such as cluster headache , which affects up to four in 1000 people (0.4%), [ 1 ] [ 2 ] [ 3 ] and is a recommended ...