When.com Web Search

  1. Ads

    related to: distance between 11kv pole to ground circuit tester kit walmart

Search results

  1. Results From The WOW.Com Content Network
  2. Ground continuity monitor - Wikipedia

    en.wikipedia.org/wiki/Ground_continuity_monitor

    A GCM or ground continuity monitor (also called a ground integrity monitor or ground continuity tester) is an electrical safety device that monitors the impedance to ground of a temporary electrical circuit and can provide indication (or protective trip) in the event impedance rises to an unsafe value. A GCM is either an external testing device ...

  3. Earth-return telegraph - Wikipedia

    en.wikipedia.org/wiki/Earth-return_telegraph

    A telegraph line between two telegraph offices, like all electrical circuits, requires two conductors to form a complete circuit. This usually means two distinct metal wires in the circuit, but in the earth-return circuit one of these is replaced by connections to earth (also called ground) to complete the circuit. Connection to earth is made ...

  4. Single-wire earth return - Wikipedia

    en.wikipedia.org/wiki/Single-wire_earth_return

    Since the bulk of the transmission line has low resistance attachments to earth, excessive ground currents from shorts and geomagnetic storms are more rare than in conventional metallic-return systems. So, SWER has fewer ground-fault circuit-breaker openings to interrupt service. [3]

  5. Grounding resistance tester - Wikipedia

    en.wikipedia.org/wiki/Grounding_resistance_tester

    The first soil resistance measuring instrument was invented in the 1950s by Evershed & Vignoles Meggers who made the first insulation and earth resistance testers. [2] One of the most used analog grounding testers in USSR were М416. [3] From the 21st century several companies produced digital earth resistance meters and testers.

  6. Earth-leakage circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    An earth-leakage circuit breaker (ELCB) is a safety device used in electrical installations to prevent shock. It consists of either a current sensing mechanism, or a voltage sensing mechanism. Such a protection mechanism may be found in the form of distribution board modules, standalone devices, and special sockets (aka receptacles ).

  7. Delta-wye transformer - Wikipedia

    en.wikipedia.org/wiki/Delta-wye_transformer

    An example would be a distribution transformer with a delta primary, running on three 11 kV phases with no neutral or earth required, and a star (or wye) secondary providing a 3-phase supply at 415 V, with the domestic voltage of 240 available between each phase and the earthed (grounded) neutral point.