Figure 1 - Humphrey field analyser. Humphrey field analyser (HFA) is a tool for measuring the human visual field that is commonly used by optometrists, orthoptists and ophthalmologists, particularly for detecting monocular visual field. [1] The results of the analyser identify the type of vision defect.
The normal (monocular) human visual field extends to approximately 60 degrees nasally (toward the nose, or inward) from the vertical meridian in each eye, to 107 degrees temporally (away from the nose, or outwards) from the vertical meridian, and approximately 70 degrees above and 80 below the horizontal meridian. [7] [1] [8] [9]
Perimetry or campimetry is one way to systematically test the visual field. [1] [failed verification] It is the systematic measurement of differential light sensitivity in the visual field by the detection of the presence of test targets on a defined background. Perimetry more carefully maps and quantifies the visual field, especially at the ...
Visual perception is the ability to interpret information and surroundings from visible light reaching the eye. The resulting perception is also known as eyesight , sight or vision . The various physiological components involved in vision are referred to collectively as the visual system , and are the focus of much research in psychology ...
Any pathological process in the visual system, even in older humans beyond the critical period, will often cause decreases in visual acuity. Thus measuring visual acuity is a simple test in accessing the health of the eyes, the visual brain, or pathway to the brain. Any relatively sudden decrease in visual acuity is always a cause for concern.
If the analogy of the eye's retina working as a sensor is drawn upon, the corresponding concept in human (and much of animal vision) is the visual field. [2] It is defined as "the number of degrees of visual angle during stable fixation of the eyes". [3] Note that eye movements are excluded in the visual field's definition.
Eye tracking device Scientists track eye movements in glaucoma patients to check vision impairment while driving. Eye tracking is the process of measuring either the point of gaze (where one is looking) or the motion of an eye relative to the head. An eye tracker is a device for measuring eye positions and eye movement.
testing visual acuity Red green goggles (red - right side & green - left side) used in Worth 4 dot test, diplopia testing Prisms: to measure the degree of squints; in other instruments; refractive correction; etc. Placido's disc: to assess the condition of the corneal surface Retinoscope