  2. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    Controls for the reclosers range from the original electromechanical systems to digital electronics with metering and SCADA functions. The ratings of reclosers run from 2.4–38 kV for load currents from 10–1200 A and fault currents from 1–16 kA. [7] [8] On a 3-phase circuit, a recloser is more beneficial than three separate fuse cutouts.

  3. Outage management system - Wikipedia

    en.wikipedia.org/wiki/Outage_management_system

    Outage management systems are also commonly integrated with SCADA systems which can automatically report the operation of monitored circuit breakers and other intelligent devices such as SCADA reclosers. Another system that is commonly integrated with an outage management system is a mobile data system. This integration provides the ability for ...

  4. Talk:Recloser - Wikipedia

    en.wikipedia.org/wiki/Talk:Recloser

    We want to be a little careful - reclosers are only used on distribution circuits, not on the "grid" (high voltage transmission). True, some circuit breakers on transmission may automatically reclose but that's a special-purpose application and HV transmission circuit breakers aren't called "reclosers".

  5. Substation - Wikipedia

    en.wikipedia.org/wiki/Substation

    A circuit breaker is used as a protection device to interrupt fault currents automatically, and may be used to switch loads on and off, or to cut off a line when power is flowing in the 'wrong' direction. When a large fault current flows through the circuit breaker, this is detected through the use of current transformers. The magnitude of the ...

  6. Automatic test switching - Wikipedia

    en.wikipedia.org/wiki/Automatic_test_switching

    Reed relays have actuation times of 0.5 ms to 2 ms and long life. By design, reed relays can only handle a portion of the signal range that electromechanical relays can offer. But they do provide a useful trade-off between increasing speed and maintaining signal integrity. Solid-state relays can switch the fastest and have essentially infinite ...

  7. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    For example, a short circuit is a fault in which a live wire touches a neutral or ground wire. An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker.

  8. Vacuum interrupter - Wikipedia

    en.wikipedia.org/wiki/Vacuum_interrupter

    Its fatigue life is affected by heat conducted from the arc. To enable them to meet the requirements for high endurance in real practice, the bellows are regularly subjected to an endurance test every three months. The test is carried out in a fully automatic test cabin with the travels adjusted to the respective type.

  9. Remote racking system - Wikipedia

    en.wikipedia.org/wiki/Remote_racking_system

    By permitting the automatic racking of the circuit breaker from a remote location, the remote racking systems move service personnel outside the arc flash protection boundary, thus reducing the need for a full-body arc flash hazard suit. A remote switch operator is used to remotely operate various types and styles of circuit breakers and controls.