When.com Web Search

  1. Ads

    related to: single pole switch with overload

Search results

  1. Results From The WOW.Com Content Network
  2. Relay - Wikipedia

    en.wikipedia.org/wiki/Relay

    SPST-NC (Single-Pole Single-Throw, Normally-Closed) relays have a single Form B or break contact. As with an SPST-NO relay, such a relay has four terminals in total. SPDT (Single-Pole Double-Throw) relays have a single set of Form C, break before make or transfer contacts. That is, a common terminal connects to either of two others, never ...

  3. Korndörfer autotransformer starter - Wikipedia

    en.wikipedia.org/wiki/Korndörfer_Autotransformer...

    The Korndorfer starter can be used manually. Newer devices provide full automatic operation, which in addition would have: triple-pole line contactor (switch), start contactor, running contactor, three single-pole overload relays, autotransformer with a set tap-changing links, a suitable timer, and start and stop pushbuttons.

  4. Magnetic starter - Wikipedia

    en.wikipedia.org/wiki/Magnetic_starter

    A magnetic starter has a contactor and an overload relay, which will open the control voltage to the starter coil if it detects an overload on a motor. [1] [2] The overload relay opens a set of contacts that are wired in series with the supply to the contactor feeding the motor. The characteristics of the heaters can be matched to the motor so ...

  5. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  6. Mercury switch - Wikipedia

    en.wikipedia.org/wiki/Mercury_switch

    A Single-Pole, Single-Throw (SPST) mercury switch on millimetre graph paper, device length approximately 1.5 cm Another mercury switch design. A mercury switch is an electrical switch that opens and closes a circuit when a small amount of the liquid metal mercury connects metal electrodes to close the circuit. There are several different basic ...

  7. Switch - Wikipedia

    en.wikipedia.org/wiki/Switch

    Single pole, single throw: One-way: Two-way: A simple on-off switch: The two terminals are either connected together or disconnected from each other. An example is a light switch. SPST-NO. Form A [4] Single pole, single throw, normally open A simple on-off switch. The two terminals are normally disconnected (open) and are closed when the switch ...