When.com Web Search

  1. Ads

    related to: stop valve leaks when closed tube frequency is higher than 100 degrees

Search results

  1. Results From The WOW.Com Content Network
  2. Valve leakage - Wikipedia

    en.wikipedia.org/wiki/Valve_leakage

    Class IV valves have no more than 0.01% leakage under those conditions; this tends to require multiple graphite piston rings or a single Teflon piston ring, and lapped metal seats. Class V valves leak less than 5 × 10 −12 cubic metres, per second, per bar of pressure differential, per millimetre of port diameter, of water when tested at the ...

  3. Control grid - Wikipedia

    en.wikipedia.org/wiki/Control_grid

    A valve can contain more than one control grid. The hexode contains two such grids, one for a received signal and one for the signal from a local oscillator. The valve's inherent non-linearity causes not only both original signals to appear in the anode circuit, but also the sum and difference of those signals.

  4. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    There is a variety of manufacturers of these gauges, but most utilize either a three-valve or a five-valve design to test the RPZD in different ways. In the UK , [ 6 ] Illinois, New York , [ 7 ] Texas , [ 8 ] and Missouri ( RsMO 10c60-11 ), the RPZD valve must be tested at least every 12 months by an accredited tester.

  5. Downhole safety valve - Wikipedia

    en.wikipedia.org/wiki/Downhole_safety_valve

    The full name for this most common type of downhole safety valve is a Tubing Retrievable Surface Controlled Sub-Surface Valve, shortened in completion diagrams to TRSCSSV. If a tubing retrievable valve fails, rather than go to the expense of a workover, a "wireline retrievable" valve may be used instead.

  6. Voltage-regulator tube - Wikipedia

    en.wikipedia.org/wiki/Voltage-regulator_tube

    The Corona VR tube is a high-voltage version that is filled with hydrogen at close to atmospheric pressure, and is designed for voltages ranging from 400 V to 30 kV at tens of microamperes. It has a coaxial form; the outer cylindrical electrode is the cathode and the inner one is the anode.

  7. Mechanism of diving regulators - Wikipedia

    en.wikipedia.org/wiki/Mechanism_of_diving_regulators

    The effect is for the interstage pressure to rise until either the next breath is drawn, or the pressure exerts more force on the second stage valve than can be resisted by the spring, and the valve opens briefly, often with a popping sound, to relieve the pressure. the frequency of the popping pressure relief depends on the flow in the second ...