A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
The calibration curve that does not use the internal standard method ignores the uncertainty between measurements. The coefficient of determination (R 2) for this plot is 0.9985. In the calibration curve that uses the internal standard, the y-axis is the ratio of the nickel signal to the yttrium signal.
Ordinary least squares regression of Okun's law.Since the regression line does not miss any of the points by very much, the R 2 of the regression is relatively high.. In statistics, the coefficient of determination, denoted R 2 or r 2 and pronounced "R squared", is the proportion of the variation in the dependent variable that is predictable from the independent variable(s).
For example, if the GPC calibration curve is known for polystyrene in toluene, polyethylene in toluene can be run in a GPC and the molecular weight of polyethylene can be found according to the polystyrene calibration curve via the above equation. [3]
Isotope dilution calibration plots sometimes show nonlinear relationships and in practice polynomial fitting is often performed to empirically describe such curves. [14] When calibration plots are markedly nonlinear, one can bypass the empirical polynomial fitting and employ the ratio of two linear functions (known as Padé approximant) which ...
The calibration curve for the southern hemisphere is known as the SHCal as opposed to the IntCal for the northern hemisphere; the most recent version was published in 2020. There is also a curve for the period after 1955, where radiocarbon levels were artificially inflated due to atomic bomb testing, varying with latitude, known as Bomb Cal ...
Using the calibration curve method, the analyst can calibrate the spectrometer with a pure silver aqueous solutions, and use the calibration graph to determine the amount of silver present in the waste samples. This method, however, assumes the pure aqueous solution of silver and a photographic waste sample have the same matrix and therefore ...
Plotting the ratio of the analyte signal to the internal standard signal against the analyte concentration results in a calibration curve. Similar to the external calibration curve, the internal calibration curve also allows to calculate the concentration of analyte in an unknown sample. [7]