When.com Web Search

  1. Ads

    related to: scanning white light interferometry zygo therapy

Search results

  1. Results From The WOW.Com Content Network
  2. White light interferometry - Wikipedia

    en.wikipedia.org/wiki/White_light_interferometry

    Figure 1: Schematic layout of a White-light Interferometer. A CCD image sensor like those used for digital photography is placed at the point where the two images are superimposed. A broadband “white light” source is used to illuminate the test and reference surfaces. A condenser lens collimates the light from the broadband light source.

  3. White light scanner - Wikipedia

    en.wikipedia.org/wiki/White_light_scanner

    A white light scanner (WLS) is a device for performing surface height measurements of an object using coherence scanning interferometry with spectrally-broadband, "white light" illumination. Different configurations of scanning interferometer may be used to measure macroscopic objects with surface profiles measuring in the centimeter range, to ...

  4. List of types of interferometers - Wikipedia

    en.wikipedia.org/wiki/List_of_types_of...

    Watson interferometer (microscopy) White-light interferometer (see also Optical coherence tomography, White light interferometry, and Coherence Scanning Interferometry) White-light scatterplate interferometer (white-light) (microscopy) Young's double-slit interferometer; Zernike phase-contrast microscopy

  5. Optical coherence tomography - Wikipedia

    en.wikipedia.org/wiki/Optical_coherence_tomography

    Optical coherence tomography (OCT) is an imaging technique that uses interferometry with short-coherence-length light to obtain micrometer-level depth resolution and uses transverse scanning of the light beam to form two- and three-dimensional images from light reflected from within biological tissue or other scattering media.

  6. Coherence scanning interferometry - Wikipedia

    en.wikipedia.org/wiki/Coherence_scanning...

    Coherence scanning interferometry (CSI) is any of a class of optical surface measurement methods wherein the localization of interference fringes during a scan of optical path length provides a means to determine surface characteristics such as topography, transparent film structure, and optical properties.

  7. Interferometry - Wikipedia

    en.wikipedia.org/wiki/Interferometry

    Figure 1. The light path through a Michelson interferometer.The two light rays with a common source combine at the half-silvered mirror to reach the detector. They may either interfere constructively (strengthening in intensity) if their light waves arrive in phase, or interfere destructively (weakening in intensity) if they arrive out of phase, depending on the exact distances between the ...

  8. Interferometric microscopy - Wikipedia

    en.wikipedia.org/wiki/Interferometric_microscopy

    Similar techniques allows scanning and precise detection of small particles. [3] As the combined image keeps both amplitude and phase information, the interferometric microscopy can be especially efficient for the phase objects, [ 3 ] allowing detection of light variations of index of refraction, which cause the phase shift or the light passing ...

  9. Mirau interferometer - Wikipedia

    en.wikipedia.org/wiki/Mirau_interferometer

    A Mirau interferometer works on the same basic principle as a Michelson interferometer. The difference between the two is in the physical location of the reference arm. [1] The reference arm of a Mirau interferometer is located within a microscope objective assembly. It is named after André Henri Mirau, who filed a patent on the concept in ...