When.com Web Search

  1. Ads

    related to: friedland doorbell transformer wiring diagram 480v to 120 240 watt

Search results

  1. Results From The WOW.Com Content Network
  2. Doorbell - Wikipedia

    en.wikipedia.org/wiki/Doorbell

    A doorbell transformer steps down the 120 or 240-volt AC electrical power to a lower voltage, typically 6 to 24 volts. The transformer's other terminal connects to one of three terminals on the signaling device. Another terminal is connected to a wire that travels to the other terminal on the button.

  3. File:Doorbell Wiring Pictorial Diagram.svg - Wikipedia

    en.wikipedia.org/wiki/File:Doorbell_Wiring...

    English: Pictorial diagram of electric doorbell wiring with a dual-solenoid chime, front door pushbutton switch and back door pushbutton switch. Date 13 November 2013, 20:03:54

  4. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    A transformer supplying a three-wire distribution system has a single-phase input (primary) winding. The output (secondary) winding has a center tap connected to a grounded neutral. As shown in Fig. 1, either end to center has half the voltage of end-to-end. Fig. 2 illustrates the phasor diagram

  5. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Lighting and general purpose receptacles are at 120 volts AC, with larger devices fed by three wire single-phase circuits at 240 volts. In commercial construction, three-phase circuits are often used. Common 3 phase configurations within a building are 208v/120 wye, 120/240 center tapped delta and 480v/277v wye. Lighting is usually fed by 277 V ...

  6. Electric power distribution - Wikipedia

    en.wikipedia.org/wiki/Electric_power_distribution

    Closer to the customer, a distribution transformer steps the primary distribution power down to a low-voltage secondary circuit, usually 120/240 V in the US for residential customers. The power comes to the customer via a service drop and an electricity meter. The final circuit in an urban system may be less than 15 metres (50 ft) but may be ...

  7. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    Phasor diagram showing 240 V delta and center-tapped phase (a–c) creating two 120 V pairs. Consider the low-voltage side of a 120/240 V high leg delta connected transformer, where the b phase is the high leg. The line-to-line voltage magnitudes are all the same: = = =.

  8. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    A "transformer bank", widely used in North America: three single-phase transformers connected to make a 3-phase transformer. The low-voltage secondary windings are attached to three or four terminals on the transformer's side. In North American residences and small businesses, the secondary is often the split-phase 120/240-volt system. The 240 ...

  9. Single-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Single-phase_electric_power

    Single-phase motors may have taps to allow their use on either 208-volt or 240-volt supply. A single-phase load may be powered directly from a three-phase distribution transformer in two ways: by connection between one phase and neutral or by connection between two phases. These two give different voltages from a given supply.