Uncovered concrete dries from the top down. Concrete moisture meters measure only the top inch at most [5] and this area is drier than the concrete further down. Once a floor covering has been installed the moisture in the slab equilibrates. In order to ensure the equilibrated moisture will be a safe level [6] for a floor covering, a relative ...
Concrete creep is essentially the sagging of concrete over time. Creep and shrinkage of concrete are two physical properties of concrete.The creep of concrete, which originates from the calcium silicate hydrates (C-S-H) in the hardened Portland cement paste (which is the binder of mineral aggregates), is fundamentally different from the creep of metals and polymers.
Epoxy moisture control systems are chemical barriers that are used to prevent moisture damage to flooring. Excessive moisture vapor emissions in concrete slabs can mean significant, expensive damage to a flooring installation. Hundreds of millions of dollars are spent annually just in the United States to correct moisture-related problems in ...
Concrete has a very low coefficient of thermal expansion, and as it matures concrete shrinks. All concrete structures will crack to some extent, due to shrinkage and tension. Concrete which is subjected to long-duration forces is prone to creep. The density of concrete varies, but is around 2,400 kilograms per cubic metre (150 lb/cu ft). [1]
Damp proofing in construction is a type of moisture control applied to building walls and floors to prevent moisture from passing into the interior spaces. Dampness problems are among the most frequent problems encountered in residences. DPC visible between concrete foundation and brickwork.
It also causes water bleeding at the surface of concrete slabs or rafts (with a dusty surface left after water evaporation). For all the afore mentioned reasons, it is strictly forbidden to add extra water to a ready-mix concrete truck when the delivery time is exceeded, and the concrete becomes difficult to pour because it starts to set. Such ...
resist the passage of moisture from the ground to the inside of the building; and; not be damaged by moisture from the ground and not carry moisture from the ground to any part which would be damaged by it, and, if the wall is an external wall:
The steel shuttering pinches the top surface of a concrete slab due to the weight of the next slab being constructed. Concrete slabs, block walls and pipelines are susceptible to cracking during ground settlement, seismic tremors or other sources of vibration, and also from expansion and contraction during adverse temperature changes.