  2. Earthing system - Wikipedia

    en.wikipedia.org/wiki/Earthing_system

    The "local" earth/ground electrode provides "system grounding" [13] at each building where it is installed. The "Grounded" current carrying conductor is the system "neutral". [clarification needed] Australian and New Zealand standards use a modified protective multiple earthing (PME [14]) system called multiple earthed neutral (MEN).

  3. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    This is called "system grounding" and most electrical systems are required to be grounded. The U.S. NEC and the UK's BS 7671 list systems that are required to be grounded. According to the NEC, the purpose of connecting an electrical system to the physical ground (earth) is to limit the voltage imposed by lightning events and contact with ...

  4. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    Neutral wires are usually connected at a neutral bus within panelboards or switchboards, and are "bonded" to earth ground at either the electrical service entrance, or at transformers within the system. For electrical installations with split-phase (three-wire single-phase) service, the neutral point of the system is at the center-tap on the ...

  5. Ground loop (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_loop_(electricity)

    The diagram shows leakage current from an appliance such as an electric motor A flowing through the building's ground system G to the neutral wire at the utility ground bonding point at the service panel. The ground loop between components C1 and C2 creates a second parallel path for the current. [8]

  6. Isolated ground - Wikipedia

    en.wikipedia.org/wiki/Isolated_ground

    An isolated ground (IG) (or Functional Earth (FE) in European literature) is a ground connection to a local earth electrode from equipment where the main supply uses a different earthing arrangement, one of the common earthing arrangements used with domestic mains supplies.

  7. TIA-607-B - Wikipedia

    en.wikipedia.org/wiki/TIA-607-B

    Following the bonding of telecom infrastructure components, the entire system must be bonded to the building's main ground, which is sometimes also referred to as a grounding electrode system. References

  8. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Hot is any line or neutral conductor (wire or otherwise) connected with an electrical system that has electric potential relative to electrical ground or line to neutral. Ground is a safety conductor with a low impedance path to earth. It is often called the "ground wire," or safety ground. It is either bare or has green insulation. [1]

  9. Groundbed - Wikipedia

    en.wikipedia.org/wiki/Groundbed

    For building electrical grounding systems or earthing systems, there is a low resistance conductor bonding the metalwork and this is connected to a groundbed. The electrodes for electrical grounding are often called ground rods and are often made from steel with a copper clad surface – typically 1 to 2 m long and 20 millimetres (0.79 in) in ...