When.com Web Search

  1. Ads

    related to: commercial ductwork sizing chart

Search results

  1. Results From The WOW.Com Content Network
  2. Process duct work - Wikipedia

    en.wikipedia.org/wiki/Process_Duct_Work

    Duct plate 3/16", or thinner, may dishpan, or make noise, and should be avoided. Rectangular duct section properties are calculated from the distance between the upper to lower duct corners of the ductwork The flanges areas are based on the size of corner angles plus duct plate width based on the plate thickness ratio of 16*t.

  3. Duct (industrial exhaust) - Wikipedia

    en.wikipedia.org/wiki/Duct_(industrial_exhaust)

    Industrial exhaust ducts are pipe systems that connect hoods to industrial chimneys through other components of exhaust systems like fans, collectors, etc. Ducts are low-pressure pneumatic conveyors to convey dust, particles, shavings, fumes, or chemical hazardous components from air in the vicinity to a shop floor or any other specific locations like tanks, sanding machines, or laboratory hoods.

  4. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    Ducts commonly also deliver ventilation air as part of the supply air. As such, air ducts are one method of ensuring acceptable indoor air quality as well as thermal comfort. A duct system is also called ductwork. Planning (laying out), sizing, optimizing, detailing, and finding the pressure losses through a duct system is called duct design. [2]

  5. Register (air and heating) - Wikipedia

    en.wikipedia.org/wiki/Register_(air_and_heating)

    Registers vary in size with the heating and cooling requirements of the room. [5] If a register is too small, the HVAC system will need to push air through the ducts at a faster rate in order to achieve the desired heating or cooling.

  6. Friction loss - Wikipedia

    en.wikipedia.org/wiki/Friction_loss

    Note that, in approximation, for a given value of flow volume, a step up in duct size (say from 100mm to 120mm) will reduce the friction loss by a factor of 3. Volumetric Flow Q of air at STP where friction loss per unit length Δ p / L (SI kg / m 2 / s 2 ) is, resp., 0.082, 0.245, and 0.816., for selected Nominal Duct Sizes [ 19 ] in smooth ...

  7. File:Equal-friction chart for air in metal duct (ε = 0.05mm ...

    en.wikipedia.org/wiki/File:Equal-friction_chart...

    Main page; Contents; Current events; Random article; About Wikipedia; Contact us; Donate; Pages for logged out editors learn more