When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Isolated-phase bus - Wikipedia

    en.wikipedia.org/wiki/Isolated-phase_bus

    In electrical engineering, isolated-phase bus (IPB), also known as phase-isolated bus (PIB) in some countries, is a method of construction for circuits carrying very large currents, typically between a generator and its step-up transformer in a steam or large hydroelectric power plant. Isolated phase bus during installation at the Bui Dam Ghana ...

  3. Single-line diagram - Wikipedia

    en.wikipedia.org/wiki/Single-line_diagram

    A typical one-line diagram with annotated power flows. Red boxes represent circuit breakers, grey lines represent three-phase bus and interconnecting conductors, the orange circle represents an electric generator, the green spiral is an inductor, and the three overlapping blue circles represent a double-wound transformer with a tertiary winding.

  4. Bus duct - Wikipedia

    en.wikipedia.org/wiki/Bus_duct

    A plug-in bus duct system or busway can have disconnect switches and other devices mounted on it, for example, to distribute power along a long building. Many forms of busway allow plug-in devices such as switches and motor starters to be easily moved; this provides flexibility for changes on an assembly line, for example. [4]

  5. Vector group - Wikipedia

    en.wikipedia.org/wiki/Vector_group

    The number is in units of 30 degrees. For example, a transformer with a vector group of Dy1 has a delta-connected HV winding and a wye-connected LV winding. The phase angle of the LV winding lags the HV by 30 degrees. Note that the high-voltage (HV) side always comes before the low-voltage (LV) side, regardless of which is the primary winding.

  6. Single-ended primary-inductor converter - Wikipedia

    en.wikipedia.org/wiki/Single-ended_primary...

    For this reason, the two inductors can be wound on the same core, which begins to resemble a flyback converter, the most basic of the transformer-isolated switched-mode power supply topologies. Since the voltages are the same in magnitude, their effects on the mutual inductance will be zero, assuming the polarity of the windings is correct.

  7. Current limiting reactor - Wikipedia

    en.wikipedia.org/wiki/Current_limiting_reactor

    The most common type is designed for three-phase electric power, in which three isolated inductors are each wired in series with one of the three line phases. [8] Line reactors are generally installed in motor driven equipment to limit starting current, and may be used to protect Variable-frequency drives and motors.

  8. Electrical busbar system - Wikipedia

    en.wikipedia.org/wiki/Electrical_busbar_system

    Enclosure comparison with normal wiring & with busbar system. Electrical busbar systems [1] (sometimes simply referred to as busbar systems) are a modular approach to electrical wiring, where instead of a standard cable wiring to every single electrical device, the electrical devices are mounted onto an adapter which is directly fitted to a current carrying busbar.

  9. Phase diagram - Wikipedia

    en.wikipedia.org/wiki/Phase_diagram

    The simplest phase diagrams are pressure–temperature diagrams of a single simple substance, such as water. The axes correspond to the pressure and temperature. The phase diagram shows, in pressure–temperature space, the lines of equilibrium or phase boundaries between the three phases of solid, liquid, and gas.