When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Two-phase flow - Wikipedia

    en.wikipedia.org/wiki/Two-phase_flow

    Different modes of two-phase flows. In fluid mechanics, two-phase flow is a flow of gas and liquid — a particular example of multiphase flow.Two-phase flow can occur in various forms, such as flows transitioning from pure liquid to vapor as a result of external heating, separated flows, and dispersed two-phase flows where one phase is present in the form of particles, droplets, or bubbles in ...

  3. Multiphase flow - Wikipedia

    en.wikipedia.org/wiki/Multiphase_flow

    In particular, Lockhart and Martinelli (1949) [6] presented a model for frictional pressure drop in horizontal, separated two-phase flow, introducing a parameter that is still utilised today. Between 1950 and 1960, intensive work in the aerospace and nuclear sectors triggered further studies into two-phase flow.

  4. Two-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Two-phase_electric_power

    A simplified diagram of a two-phase alternator [1] Two-phase electrical power was an early 20th-century polyphase alternating current electric power distribution system. Two circuits were used, with voltage phases differing by one-quarter of a cycle, 90°. Usually circuits used four wires, two for each phase.

  5. Power-flow study - Wikipedia

    en.wikipedia.org/wiki/Power-flow_study

    In power engineering, the power-flow study, or load-flow study, is a numerical analysis of the flow of electric power in an interconnected system. A power-flow study usually uses simplified notations such as a one-line diagram and per-unit system, and focuses on various aspects of AC power parameters, such as Voltage, voltage angles, real power and reactive power.

  6. Power system simulation - Wikipedia

    en.wikipedia.org/wiki/Power_system_simulation

    Short circuit analysis analyzes the power flow after a fault occurs in a power network. The faults may be three-phase short circuit, one-phase grounded, two-phase short circuit, two-phase grounded, one-phase break, two-phase break or complex faults. Results of such an analysis may help determine the following: Magnitude of the fault current

  7. Open energy system models - Wikipedia

    en.wikipedia.org/wiki/Open_energy_system_models

    Open electricity sector models are confined to just the electricity sector. These models invariably have a temporal resolution of one hour or less. Some models concentrate on the engineering characteristics of the system, including a good representation of high-voltage transmission networks and AC power flow. Others models depict electricity ...

  8. Electric power transmission - Wikipedia

    en.wikipedia.org/wiki/Electric_power_transmission

    A DC link therefore stabilizes the AC grid at either end, since power flow and phase angle can then be controlled independently. As an example, to adjust the flow of AC power on a hypothetical line between Seattle and Boston would require adjustment of the relative phase of the two regional electrical grids. This is an everyday occurrence in AC ...

  9. Particle-laden flow - Wikipedia

    en.wikipedia.org/wiki/Particle-laden_flow

    Particle-laden flows refers to a class of two-phase fluid flow, in which one of the phases is continuously connected (referred to as the continuous or carrier phase) and the other phase is made up of small, immiscible, and typically dilute particles (referred to as the dispersed or particle phase). Fine aerosol particles in air is an example of ...