When.com Web Search

  1. Ad

    related to: blood pressure oscillation sensor arduino example model of system

Search results

  1. Results From The WOW.Com Content Network
  2. Lumped parameter model for the cardiovascular system

    en.wikipedia.org/wiki/Lumped_parameter_model_for...

    The lumped parameter model consists in a system of ordinary differential equations that adhere to the principles of conservation of mass and momentum balance. The model is obtained exploiting the electrical analogy where the current represents the blood flow, the voltage represents the pressure difference, the electric resistance plays the role of the vascular resistance (determined by the ...

  3. Mayer waves - Wikipedia

    en.wikipedia.org/wiki/Mayer_waves

    Mayer waves are cyclic changes or waves in arterial blood pressure brought about by oscillations in the baroreceptor reflex control system. [1] [2] The waves are seen both in the ECG and in continuous blood pressure curves and have a frequency about 0.1 Hz (10-second waves).

  4. Bioinstrumentation - Wikipedia

    en.wikipedia.org/wiki/Bioinstrumentation

    A blood pressure (BP) measurement system specifically a writ-bound BP monitor works through an applanation tonometry with a hemispheric plunger set on the radial artery. Devices such as an ambulatory blood pressure improved the management of hypertension, but remain not being widely used and inconvenient.

  5. Blood pressure measurement - Wikipedia

    en.wikipedia.org/wiki/Blood_pressure_measurement

    A more accurate value of systolic blood pressure can be obtained with a sphygmomanometer and palpating the radial pulse. [11] Methods using constitutive models have been proposed to measure blood pressure from radial artery pulse. [citation needed] The diastolic blood pressure cannot be estimated by this method. The American Heart Association ...

  6. Photoplethysmogram - Wikipedia

    en.wikipedia.org/wiki/Photoplethysmogram

    The height of AC component of the photoplethysmogram is proportional to the pulse pressure, the difference between the systolic and diastolic pressure in the arteries. As seen in the figure showing premature ventricular contractions (PVCs), the PPG pulse for the cardiac cycle with the PVC results in lower amplitude blood pressure and a PPG.

  7. Baroreceptor - Wikipedia

    en.wikipedia.org/wiki/Baroreceptor

    The blood volume determines the mean pressure throughout the system, in particular in the venous side where most of the blood is held. The low-pressure baroreceptors have both circulatory and renal effects; they produce changes in hormone secretion, resulting in profound effects on the retention of salt and water ; they also influence intake of ...

  8. Surface acoustic wave sensor - Wikipedia

    en.wikipedia.org/wiki/Surface_acoustic_wave_sensor

    The fundamental measurement of a surface acoustic wave sensor is typically strain. When a diaphragm is placed between the environment at a variable pressure and a reference cavity at a fixed pressure, the diaphragm will bend in response to a pressure differential. As the diaphragm bends, the distance along the surface in compression will increase.

  9. Heart rate variability - Wikipedia

    en.wikipedia.org/wiki/Heart_rate_variability

    The respiratory rhythm contributes to sinus arrhythmia in normal unanesthetized subjects during mechanical hyperventilation with positive pressure. [37] Low-frequency oscillations [41] are associated with Mayer waves (Traube–Hering–Mayer waves) of blood pressure and is usually at a frequency of 0.1 Hz, or a 10-second period.