A mass chromatogram is a representation of mass spectrometry data as a chromatogram, where the x-axis represents time and the y-axis represents signal intensity. [1] The source data contains mass information; however, it is not graphically represented in a mass chromatogram in favor of visualizing signal intensity versus time.
Gas chromatography–mass spectrometry (GC–MS) is an analytical method that combines the features of gas-chromatography and mass spectrometry to identify different substances within a test sample. [1]
XCMS introduced the concept of nonlinear retention time alignment that allowed for the statistical assessment of the detected peaks across LCMS and GCMS datasets. [1] XCMS Online [4] was designed to facilitate XCMS analyses through a cloud portal and as a more straightforward [5] (non command driven) way to analyze, visualize and share ...
AnalyzerPro is a vendor-independent software application from SpectralWorks for processing mass spectrometry data. It can process both GC-MS and LC-MS data using qualitative and quantitative data processing and is used in metabolomics with MatrixAnalyzer for the comparison of multiple data sets.
Paul Patent 2939952 Fig5. Essentially the triple quadrupole mass spectrometer operates under the same principle as the single quadrupole mass analyzer.Each of the two mass filters (Q1 and Q3) contains four parallel, cylindrical metal rods.
The ion is selected in the second mass spectrometry stage MS2 then undergoes further fragmentation to form ion D + which is selected in the third mass spectrometry stage MS3 and detected. Multiple reaction monitoring ( MRM ) is the application of selected reaction monitoring to multiple product ions from one or more precursor ions, [ 3 ] [ 4 ...
One of the most widely used methods for headspace analysis is described by the United States Environmental Protection Agency (USEPA). Originally developed by the R.S. Kerr USEPA Laboratory in Ada, Oklahoma as a "high quality, defendable, and documented way to measure" methane, ethane, and ethene, [7] [8] RSKSOP-175 is a standard operating procedure (SOP) and an unofficial method employed by ...
Mass spectrometer (MS), also called GC-MS; highly effective and sensitive, even in a small quantity of sample. This detector can be used to identify the analytes in chromatograms by their mass spectrum. [14] Some GC-MS are connected to an NMR spectrometer which acts as a backup detector. This combination is known as GC-MS-NMR.