When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Load cell - Wikipedia

    en.wikipedia.org/wiki/Load_cell

    Input resistance: Input resistance of the load cell's bridge circuit. Measured at the positive & negative excitation leads with no load applied. Measured in ohms. Output resistance: Output resistance of the load cell's bridge circuit. Measured at the positive & negative excitation leads with no load applied. Measured in ohms.

  3. Maximum power point tracking - Wikipedia

    en.wikipedia.org/wiki/Maximum_power_point_tracking

    A load with resistance R=V/I equal to the reciprocal of this value draws the maximum power from the device. This is sometimes called the 'characteristic resistance' of the cell. This is a dynamic quantity that changes depending on the level of illumination, as well as other factors such as temperature and cell condition.

  4. Load regulation - Wikipedia

    en.wikipedia.org/wiki/Load_regulation

    The values of the resistors are selected such that R 1 gives the highest load resistance, R 1 ||R 2 gives the nominal load resistance and either R 1 ||R 2 ||R 3 or R 2 ||R 3 gives the lowest load resistance. A voltmeter is then connected in parallel to the resistors and the measured values of voltage for each load state can be used to calculate ...

  5. Maximum power transfer theorem - Wikipedia

    en.wikipedia.org/wiki/Maximum_power_transfer_theorem

    Simplified model for powering a load with resistance R L by a source with voltage V S and resistance R S.. The theorem was originally misunderstood (notably by Joule [4]) to imply that a system consisting of an electric motor driven by a battery could not be more than 50% efficient, since the power dissipated as heat in the battery would always be equal to the power delivered to the motor when ...

  6. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    Then, the real numbers of impedances and voltages can be substituted into the per-unit calculation definition to get the answers for the per-unit system. If the per-unit values are known, the real values can be obtained by multiplying by the base values. By convention, the following two rules are adopted for base quantities:

  7. Output impedance - Wikipedia

    en.wikipedia.org/wiki/Output_impedance

    Internal resistance varies with the age of a battery, but for most commercial batteries the internal resistance is on the order of 1 ohm. When there is a current through a cell, the measured e.m.f. is lower than when there is no current delivered by the cell. The reason for this is that part of the available energy of the cell is used up to ...

  8. Smith chart - Wikipedia

    en.wikipedia.org/wiki/Smith_chart

    The Smith chart (sometimes also called Smith diagram, Mizuhashi chart (水橋チャート), Mizuhashi–Smith chart (水橋スミスチャート), [1] [2] [3] Volpert–Smith chart (Диаграмма Вольперта—Смита) [4] [5] or Mizuhashi–Volpert–Smith chart) is a graphical calculator or nomogram designed for electrical and electronics engineers specializing in radio ...

  9. Load bank - Wikipedia

    en.wikipedia.org/wiki/Load_bank

    A load bank is a piece of electrical test equipment used to simulate an electrical load, to test an electric power source without connecting it to its normal operating load. [ 1 ] [ 2 ] During testing, adjustment, calibration, or verification procedures, a load bank is connected to the output of a power source, such as an electric generator ...