When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Engine–generator - Wikipedia

    en.wikipedia.org/wiki/Engine–generator

    This is a 100 kVA set. The mid-size stationary engine–generator pictured here is a 100 kVA set which produces 415 V at around 110 A. It is powered by a 6.7-liter turbocharged Perkins Phaser 1000 Series engine, and consumes approximately 27 liters of fuel an hour, on a 400-liter tank.

  3. Diesel generator - Wikipedia

    en.wikipedia.org/wiki/Diesel_generator

    Set sizes range from 8 to 30-kW (also 8 to 30-kVA single phase) for homes, small shops, and offices, with the larger industrial generators from 8-kW (11 kVA) up to 2,000-kW (2,500-kVA three phase) used for office complexes, factories, and other industrial facilities. A 2,000-kW set can be housed in a 40 ft (12 m) ISO container with a fuel tank ...

  4. Diesel rotary uninterruptible power supply - Wikipedia

    en.wikipedia.org/wiki/Diesel_rotary...

    Most forms of uninterruptible power supply (UPS) can be either powered by battery or flywheel energy. These are ready for immediate use at the instant that the mains electricity fails, but the relatively small and finite amount of stored energy they contain makes them suitable for short periods of use, typically in the order of a few dozen minutes to a couple of hours depending on the actual load.

  5. Permanent magnet synchronous generator - Wikipedia

    en.wikipedia.org/wiki/Permanent_magnet...

    A permanent magnet synchronous generator is a generator where the excitation field is provided by a permanent magnet instead of a coil. The term synchronous refers here to the fact that the rotor and magnetic field rotate with the same speed, because the magnetic field is generated through a shaft-mounted permanent magnet mechanism, and current is induced into the stationary armature.

  6. Motor–generator - Wikipedia

    en.wikipedia.org/wiki/Motor–generator

    As an example, a 250 kVA motor–generator operating at 300 ampere of full load current will require 1550 ampere of in-rush current during a re-closure after 5 seconds. This example used a fixed mounted flywheel sized to result in a 1 ⁄ 2 Hz per second slew rate. The motor–generator was a vertical type two-bearing machine with oil-bath ...

  7. Read the Transcript of Trump's Person of the Year Interview - AOL

    www.aol.com/read-transcript-trumps-person...

    Credit - Photograph by Platon for TIME. P resident-elect Donald Trump, TIME’s 2024 Person of the Year, sat down for a wide-ranging interview at his Mar-a-Lago Club in Palm Beach, Fla., on Nov ...

  8. Doubly fed electric machine - Wikipedia

    en.wikipedia.org/wiki/Doubly_fed_electric_machine

    The doubly fed generator rotors are typically wound with 2 to 3 times the number of turns of the stator. This means that the rotor voltages will be higher and currents respectively lower. Thus in the typical ±30% operational speed range around the synchronous speed, the rated current of the converter is accordingly lower which leads to a lower ...

  9. The 15 best early Black Friday sales this weekend: Toys ... - AOL

    www.aol.com/lifestyle/the-15-best-early-black...

    Ages: 12 months+. These colorful plastic blocks are a classic gift for two year olds for good reason: the large size pieces are easy for them to manipulate, and don’t pose a choking hazard like ...