  2. Contact cleaner - Wikipedia

    en.wikipedia.org/wiki/Contact_cleaner

    Contact-cleaner, also known as switch-cleaner, is a term for a chemical, or a mixture of chemicals, intended to remove or prevent the build-up of oxides or other unwanted substances on the conductive surfaces of connectors, switches, and other electronic components with moving surface-contacts, and thus reduce the contact resistance encountered.

  3. Wetting current - Wikipedia

    en.wikipedia.org/wiki/Wetting_current

    A related term sealing current (aka wetting current or fritting current) is widely used in the telecommunication industry describing a small constant DC current (typically 1-20 mA) in copper wire loops in order to avoid contact oxidation of contacts and splices.

  4. Contact protection - Wikipedia

    en.wikipedia.org/wiki/Contact_protection

    Every time the contacts of an electromechanical switch, relay or contactor are opened or closed, there is a certain amount of contact wear. If the contact is cycling without electricity (dry), the impact of the contact electrodes a slightly deformed by the resulting cold forging. [1]

  5. Contact resistance - Wikipedia

    en.wikipedia.org/wiki/Contact_resistance

    For experimental characterization, a distinction must be made between contact resistance evaluation in two-electrode systems (for example, diodes) and three-electrode systems (for example, transistors). In two-electrode systems, specific contact resistivity is experimentally defined as the slope of the I–V curve at V = 0:

  6. Multiway switching - Wikipedia

    en.wikipedia.org/wiki/Multiway_switching

    A "4-way" (intermediate) switch is a purpose built double pole, double throw (DPDT) switch, internally wired in manufacture to reverse the connections between the input and output and having only four external terminals. This switch has two pairs of "traveler" terminals that it connects either straight through, or crossed over (transposed, or ...

  7. Air purge system - Wikipedia

    en.wikipedia.org/wiki/Air_purge_system

    Blowers provide clean air to prevent contamination of electrical and optical surfaces from dirt, corrosive gases and overheating. Mains electricity is responsible for powering the blower’s motor. Different power ratings ensure that the required air flow is provided under different application conditions, duct pressures and hose lengths.

  8. Parts cleaning - Wikipedia

    en.wikipedia.org/wiki/Parts_cleaning

    Aqueous parts cleaning industrial washer. Parts cleaning is a step in various industrial processes, either as preparation for surface finishing or to safeguard delicate components. One such process, electroplating, is particularly sensitive to part cleanliness, as even thin layers of oil can hinder coating adhesion.

  9. Arc suppression - Wikipedia

    en.wikipedia.org/wiki/Arc_suppression

    Every time an electrical power device (for example: heaters, lamps, motors, transformers or similar power loads) turns on or off, its switch, relay or contactor transitions either from a CLOSED to an OPEN state ("BREAK") or from an OPEN to a CLOSED state ("MAKE"), under load, an electrical arc occurs between the two contact points (electrodes) of the switch.