When.com Web Search

  1. Ad

    related to: automatic circuit reclosers examples free standing power

Search results

  1. Results From The WOW.Com Content Network
  2. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    Controls for the reclosers range from the original electromechanical systems to digital electronics with metering and SCADA functions. The ratings of reclosers run from 2.4–38 kV for load currents from 10–1200 A and fault currents from 1–16 kA. [7] [8] On a 3-phase circuit, a recloser is more beneficial than three separate fuse cutouts.

  3. Circuit breaker (overcurrent) - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker_(overcurrent)

    Power circuit breakers and medium- and high-voltage circuit breakers used for industrial or electric power systems are designed and tested to ANSI or IEEE standards in the C37 series. For example, standard C37.16 lists preferred frame size current ratings for power circuit breakers in the range of 600 to 5000 amperes.

  4. Talk:Recloser - Wikipedia

    en.wikipedia.org/wiki/Talk:Recloser

    The opening sentence reads: "In electric power distribution, automatic circuit reclosers (ACRs) are a class of switchgear designed for use on overhead electricity distribution networks to detect and interrupt transient faults." I suggest that the word 'overhead' should be deleted.

  5. Single-wire earth return - Wikipedia

    en.wikipedia.org/wiki/Single-wire_earth_return

    From the earth stake, the current eventually finds its way back to the main step-up transformer at the head of the line, completing the circuit. [3] SWER is therefore a practical example of a phantom loop. In areas with higher-resistance soil, the grounding rod can float to higher voltages, wasting energy.

  6. Fuse cutout - Wikipedia

    en.wikipedia.org/wiki/Fuse_cutout

    An overcurrent caused by a fault in the transformer or customer circuit will cause the fuse to melt and the switch mechanism to visibly open, disconnecting the transformer from the line. The device can also be opened manually by utility linemen standing on the ground and using a long insulating stick called a " hot stick ".

  7. Vacuum interrupter - Wikipedia

    en.wikipedia.org/wiki/Vacuum_interrupter

    In 1956, Hugh C. Ross at Jennings Radio Manufacturing Corporation revolutionized the high-frequency-circuit vacuum switch and produced a vacuum switch with a rating of 15 kV at 200 A. Five years later, Thomas H. Lee at General Electric produced the first vacuum circuit breakers [2] [3] with a rated voltage of 15 kV at short-circuit breaking ...

  8. Power system protection - Wikipedia

    en.wikipedia.org/wiki/Power_system_protection

    Power system protection is a branch of electrical power engineering that deals with the protection of electrical power systems from faults [citation needed] through the disconnection of faulted parts from the rest of the electrical network. The objective of a protection scheme is to keep the power system stable by isolating only the components ...

  9. Transfer switch - Wikipedia

    en.wikipedia.org/wiki/Transfer_switch

    When utility power returns for a minimum time, the transfer switch will transfer the house back to utility power and command the generator to turn off, after another specified amount of "cool down" time with no load on the generator. A transfer switch can be set up to provide power only to critical circuits or to entire electrical (sub)panels.