  2. Prospective short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Prospective_short-circuit...

    The resistance path is the total resistance back through the supply transformer; to measure this an engineer will use an "earth fault loop impedance meter". The application of a low voltage allows a small current to pass from the socket back through earth to the supply transformer and distribution board.

  3. IEEE 1584 - Wikipedia

    en.wikipedia.org/wiki/IEEE_1584

    IEEE 1584-2018 is an update to IEEE 1584-2002 and was developed to help protect people from arc-flash hazard dangers. The predicted arc current and incident energy are used in selecting appropriate overcurrent protective devices and personal protective equipment (generally abbreviated as PPE), as well as defining safe working distance. Since ...

  4. Arc flash - Wikipedia

    en.wikipedia.org/wiki/Arc_flash

    The second method of selecting PPE is to perform an arc flash hazard calculation to determine the available incident arc energy. IEEE 1584 provides a guide to perform these calculations given that the maximum fault current, duration of faults, and other general equipment information is known. Once the incident energy is calculated the ...

  5. Transient recovery voltage - Wikipedia

    en.wikipedia.org/wiki/Transient_Recovery_Voltage

    Examples of TRV waveshapes. A transient recovery voltage (TRV) for high-voltage circuit breakers is the voltage that appears across the terminals after current interruption. It is a critical parameter for fault interruption by a high-voltage circuit breaker, its characteristics (amplitude, rate of rise) can lead either to a successful current interruption or to a failure (called reignition or ...

  6. Breaking capacity - Wikipedia

    en.wikipedia.org/wiki/Breaking_capacity

    Since practical calculations involve a number of approximations and estimates, some judgment is required in applying the results of a short-circuit calculation to the selection of apparatus. [4] Making capacity i.e. maximum fault current , device can carry, if it is closed in to the fault should be considered.

  7. Power system protection - Wikipedia

    en.wikipedia.org/wiki/Power_system_protection

    Current and voltage transformers to step down the high voltages and currents of the electrical power system to convenient levels for the relays to deal with; Protective relays to sense the fault and initiate a trip, or disconnection, order; Circuit breakers or RCDs to open/close the system based on relay and autorecloser commands

  8. Power system simulation - Wikipedia

    en.wikipedia.org/wiki/Power_system_simulation

    Short circuit analysis analyzes the power flow after a fault occurs in a power network. The faults may be three-phase short circuit, one-phase grounded, two-phase short circuit, two-phase grounded, one-phase break, two-phase break or complex faults. Results of such an analysis may help determine the following: Magnitude of the fault current

  9. Arc fault - Wikipedia

    en.wikipedia.org/wiki/Arc_fault

    An arc fault is a high power discharge of electricity between two or more conductors. This discharge generates heat, which can break down the wire's insulation and trigger an electrical fire. Arc faults can range in current from a few amps up to thousands of amps, and are highly variable in strength and duration.