  1. Results From The WOW.Com Content Network
  2. Circuit breaker (overcurrent) - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker_(overcurrent)

    Power circuit breakers and medium- and high-voltage circuit breakers used for industrial or electric power systems are designed and tested to ANSI or IEEE standards in the C37 series. For example, standard C37.16 lists preferred frame size current ratings for power circuit breakers in the range of 600 to 5000 amperes.

  3. Breaking capacity - Wikipedia

    en.wikipedia.org/wiki/Breaking_capacity

    The prospective short-circuit current that can occur under short circuit conditions should not exceed the rated breaking capacity of the apparatus, otherwise breaking of the current cannot be guaranteed. The current breaking capacity corresponds to a certain voltage, so an electrical apparatus may have more than one breaking capacity current ...

  4. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    The standard includes preferred current ratings and wire gauges for both International (deemed Series I) and North American (deemed Series II) applications. Series I preferred current ratings (in amps) are: 16, 32, 63, 125, 250, 400, 630 and 800, with wire gauges specified as mm 2 .

  5. Dynamic line rating for electric utilities - Wikipedia

    en.wikipedia.org/wiki/Dynamic_line_rating_for...

    Electric current passing through the conductor causes heating according to Joule's first law, resulting in the conductor expanding and the line sagging. Transmission ratings are set with a maximum allowable conductor temperature (annealing temperature) and minimum clearance rules to comply with legislation and regulation. [1]

  6. Selectivity (circuit breakers) - Wikipedia

    en.wikipedia.org/wiki/Selectivity_(circuit_breakers)

    Faults in an installation are, for example, overload and short circuit. [1] [2] There are four ways in which selectivity is achieved: [3] Current selectivity: different breaking capacities; Time selectivity: time delay before tripping of a breaker; Energy based selectivity: analysis of the current waves

  7. Utilization categories - Wikipedia

    en.wikipedia.org/wiki/Utilization_categories

    Control of small electromagnetic loads with holding current ≤ 0.2 A; e.g. contactor relays 60947-5-2 A: Protection of circuits, with no rated short-time withstand current: 60947-3 B: Protection of circuits, with a rated short-time withstand current: 60947-3 DC-1: Non Inductive or slightly inductive loads, resistance furnaces, heaters: 60947-4 ...

  8. Measurement category - Wikipedia

    en.wikipedia.org/wiki/Measurement_category

    Schematic representation of measurement categories. Measurement category is a method of classification by the International Electrotechnical Commission (IEC) [1] of live electric circuits used in measurement and testing of installations and equipment, usually in the relation within a building (residential or industrial).

  9. Ampacity - Wikipedia

    en.wikipedia.org/wiki/Ampacity

    Electrical code rules will give ratings for wiring where short-term loads are present, for example, in a hoisting motor. For systems such as underground power transmission cables, evaluation of the short-term over-load capacity of the cable system requires a detailed analysis of the cable's thermal environment and an evaluation of the ...