When.com Web Search

  1. Ads

    related to: why does a thermocouple fail fast in ac

Search results

  1. Results From The WOW.Com Content Network
  2. Thermocouple - Wikipedia

    en.wikipedia.org/wiki/Thermocouple

    A thermocouple (the right most tube) inside the burner assembly of a water heater Thermocouple connection in gas appliances. The end ball (contact) on the left is insulated from the fitting by an insulating washer. The thermocouple line consists of copper wire, insulator and outer metal (usually copper) sheath which is also used as ground. [33]

  3. Seebeck coefficient - Wikipedia

    en.wikipedia.org/wiki/Seebeck_coefficient

    The Seebeck coefficient (also known as thermopower, [1] thermoelectric power, and thermoelectric sensitivity) of a material is a measure of the magnitude of an induced thermoelectric voltage in response to a temperature difference across that material, as induced by the Seebeck effect. [2]

  4. Alternating current - Wikipedia

    en.wikipedia.org/wiki/Alternating_current

    A schematic representation of long distance electric power transmission. From left to right: G=generator, U=step-up transformer, V=voltage at beginning of transmission line, Pt=power entering transmission line, I=current in wires, R=total resistance in wires, Pw=power lost in transmission line, Pe=power reaching the end of the transmission line, D=step-down transformer, C=consumers.

  5. Test probe - Wikipedia

    en.wikipedia.org/wiki/Test_probe

    A thermocouple probe. Temperature probes are used to make contact measurements of surface temperatures. They employ a temperature sensor such as a thermistor, thermocouple, or RTD, to produce a voltage that varies with temperature. In the case of thermistor and RTD probes, the sensor must be electrically stimulated to produce a voltage, whereas ...

  6. Leakage (electronics) - Wikipedia

    en.wikipedia.org/wiki/Leakage_(electronics)

    Leakage may also mean an unwanted transfer of energy from one circuit to another. For example, magnetic lines of flux will not be entirely confined within the core of a power transformer; another circuit may couple to the transformer and receive some leaked energy at the frequency of the electric mains, which will cause audible hum in an audio application.

  7. Highly accelerated life test - Wikipedia

    en.wikipedia.org/wiki/Highly_accelerated_life_test

    The equipment under test must be monitored so that if the equipment fails under test, the failure is detected. Monitoring is typically performed with thermocouple sensors, vibration accelerometers, multimeters and data loggers. Common causes of failures during HALT are poor product design, workmanship, and poor manufacturing.

  8. Failure of electronic components - Wikipedia

    en.wikipedia.org/wiki/Failure_of_electronic...

    A sudden fail-open fault can cause multiple secondary failures if it is fast and the circuit contains an inductance; this causes large voltage spikes, which may exceed 500 volts. A broken metallisation on a chip may thus cause secondary overvoltage damage. [ 1 ]

  9. Thermoelectric materials - Wikipedia

    en.wikipedia.org/wiki/Thermoelectric_materials

    The efficiency of a thermoelectric device for electricity generation is given by , defined as =.. The maximum efficiency of a thermoelectric device is typically described in terms of its device figure of merit where the maximum device efficiency is approximately given by [7] = + ¯ + ¯ +, where is the fixed temperature at the hot junction, is the fixed temperature at the surface being cooled ...

  1. Ad

    related to: why does a thermocouple fail fast in ac