When.com Web Search

  1. Ads

    related to: transformer with 2 secondary windings and 6 point 4 blade attachment for skid

Search results

  1. Results From The WOW.Com Content Network
  2. Rotary variable differential transformer - Wikipedia

    en.wikipedia.org/wiki/Rotary_variable...

    The transformer has a rotor which can be turned by an external force. The transformer acts as an electromechanical transducer that outputs an alternating current (AC) voltage proportional to the angular displacement of its rotor shaft. In operation, an alternating current (AC) voltage is applied to the transformer primary to energize the RVDT.

  3. Resolver (electrical) - Wikipedia

    en.wikipedia.org/wiki/Resolver_(electrical)

    The two other windings are on the bottom, wound on a lamination. They are configured at 90 degrees from each other. The rotor houses a coil, which is the secondary winding of the turning transformer, and a separate primary winding in a lamination, exciting the two two-phase windings on the stator.

  4. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    A planar transformer Exploded view: the spiral primary "winding" on one side of the PCB (the spiral secondary "winding" is on the other side of the PCB) Manufacturers either use flat copper sheets or etch spiral patterns on a printed circuit board to form the "windings" of a planar transformer , replacing the turns of wire used to make other types.

  5. Zigzag transformer - Wikipedia

    en.wikipedia.org/wiki/Zigzag_transformer

    Nine-winding, three-phase transformers typically have three primaries and six identical secondary windings, which can be used in zigzag winding connection as pictured. [1] A conventional six-winding, grounding transformer or zigzag bank, [1] with the same winding and core quantity as a conventional three-phase transformer, can also be used in ...

  6. Delta-wye transformer - Wikipedia

    en.wikipedia.org/wiki/Delta-wye_transformer

    An example would be a distribution transformer with a delta primary, running on three 11 kV phases with no neutral or earth required, and a star (or wye) secondary providing a 3-phase supply at 415 V, with the domestic voltage of 240 available between each phase and the earthed (grounded) neutral point. The delta winding allows third-harmonic ...

  7. Vector group - Wikipedia

    en.wikipedia.org/wiki/Vector_group

    Thus 1 = 30°, 2 = 60°, 3 = 90°, 6 = 180° and 12 = 0° or 360°. According to the IEC60076-1 standard, the notation is HV-LV in sequence. For example, a step-up transformer with a delta-connected primary and a wye-connected secondary is still labeled as 'Yd1'. The 1 indicates the LV winding lags the HV by 30 degrees. [1]