Search results
Results From The WOW.Com Content Network
While moving the streak or spot of light through the pupil across the retina, the examiner observes the relative movement of the reflex or manually places lenses over the eye (using a phoropter or trial frame and trial lenses) to "neutralize" the reflex. [2] Static retinoscopy is a type of retinoscopy used in determining a patient's refractive ...
oculus uterque (both eyes) PD Pupillary distance PERRLA Pupils equal, round, reactive to light and accommodation PH Pinhole see Pinhole occluder and Visual_acuity#Legal_definitions: PHNI Pinhole No Improvement see Pinhole occluder and Visual_acuity#Legal_definitions: PHVA Pinhole Visual Acuity: PL Perception of light POH / PrOH Previous ocular ...
The pupil is a hole through which the eye's interior can be viewed. For better viewing, the pupil can be opened wider (dilated; mydriasis) before ophthalmoscopy using medicated eye drops (dilated fundus examination). However, undilated examination is more convenient (albeit not as comprehensive), and is the most common type in primary care.
There are two techniques used to assess the red reflex listed below. Both are noninvasive, inexpensive, and quick. Dilation of the eyes is unnecessary and not recommended due to the theoretical but rarely seen risks of sympathomimetics and antimuscarinic systemic effects – tachycardia (fast heart rate), hypertension (high blood pressure), and arrhythmia (abnormal heart rhythm).
Visual acuity is the eyes ability to detect fine details and is the quantitative measure of the eye's ability to see an in-focus image at a certain distance. The standard definition of normal visual acuity (20/20 or 6/6 vision) is the ability to resolve a spatial pattern separated by a visual angle of one minute of arc.
A contracted pupil during sleep may be an indication the brain is replaying new memories while a dilated one may hint at older memories being relived, a new study suggests. The study, published in ...
The monocular estimate method or monocular estimation method is a form of dynamic retinoscopy widely used to objectively measure accommodative response. [ 1 ] [ 2 ] Values normally attained when performing MEM are between +0.25 and +0.50 diopters .
Retinal scanning also has medical application. Communicable illnesses such as AIDS, syphilis, malaria, chicken pox and Lyme disease as well as hereditary diseases like leukemia, lymphoma, and sickle cell anemia affect the eyes. Pregnancy also affects the eyes.